Certificate holders

Subtype

Air to water heat pump 5K

Certificate Holder
Quatt B.V.
Koningin Wilhelminaplein 29
1062 HJ Amsterdam
Netherlands
Registration number
011-1W1135
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Air to water heat pump 5K
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,480 kg

Certification Date
27.10.2025
Testing basis
HP KEYMARK certification scheme rules rev. 15
Testing laboratory
TÜV Rheinland (GuangDong) Ltd., CN
Generate PDF Export model CSV
  • Number of models 1

Models

AMH6
Configure model
Model name
AMH6
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

5.85 kW

5.51 kW

El input

1.14 kW

1.73 kW

COP

5.14

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

7.65 kW

6.57 kW

SCOP

4.89

3.85

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.77 kW

5.81 kW

COP Tj = -7°C

2.98

2.46

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.97 kW

3.61 kW

COP Tj = +2°C

4.73

3.62

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.62 kW

2.42 kW

COP Tj = +7°C

6.49

5.11

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

2.13 kW

2.12 kW

COP Tj = 12°C

9.36

7.03

Cdh Tj = +12 °C

0.930

0.950

Pdh Tj = Tbiv

6.77 kW

5.81 kW

COP Tj = Tbiv

2.98

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.30 kW

5.22 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.73

2.22

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

55 °C

55 °C

Poff

9 W

9 W

PTO

15 W

15 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.35 kW

1.35 kW

Annual energy consumption Qhe

3233 kWh