0,480 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
5.85 kW
5.51 kW
El input
1.14 kW
1.73 kW
COP
5.14
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
50 dB(A)
51 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
193 %
150 %
Prated
7.65 kW
6.57 kW
SCOP
4.89
3.85
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.77 kW
5.81 kW
COP Tj = -7°C
2.98
2.46
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.97 kW
3.61 kW
COP Tj = +2°C
4.73
3.62
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.62 kW
2.42 kW
COP Tj = +7°C
6.49
5.11
Cdh Tj = +7 °C
0.960
0.970
Pdh Tj = 12°C
2.13 kW
2.12 kW
COP Tj = 12°C
9.36
7.03
Cdh Tj = +12 °C
0.930
0.950
Pdh Tj = Tbiv
6.77 kW
5.81 kW
COP Tj = Tbiv
2.98
2.36
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.30 kW
5.22 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.73
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
55 °C
55 °C
Poff
9 W
9 W
PTO
15 W
15 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.35 kW
1.35 kW
Annual energy consumption Qhe
3233 kWh
3552 kWh