Thermia Calibra E 12

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700111 / Issue 2
Certification Body
RISE CERT
Subtype title
Thermia Calibra E 12
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R452B
Mass of Refrigerant

1,300 kg

Certification Date
25.08.2021
Testing basis
EN 14511:2018, EN 14825:2018, EN 12102:2017
Testing laboratory
RISE Research Institutes of Sweden
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Thermia Calibra E 12 400V
Configure model
Model name
Thermia Calibra E 12 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh

Thermia Calibra E 12 Duo 400V
Configure model
Model name
Thermia Calibra E 12 Duo 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh

Thermia Calibra E 12 230V
Configure model
Model name
Thermia Calibra E 12 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

34 dB(A)

34 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh

Thermia Calibra E 12 Duo 230V
Configure model
Model name
Thermia Calibra E 12 Duo 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

5.21 kW

8.42 kW

El input

1.09 kW

2.84 kW

COP

4.78

2.96

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

222 %

164 %

Prated

11.52 kW

10.57 kW

SCOP

5.76

4.29

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.52 kW

10.57 kW

COP Tj = +2°C

4.39

2.96

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.41 kW

6.79 kW

COP Tj = +7°C

5.38

3.81

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.29 kW

3.02 kW

COP Tj = 12°C

6.47

5.12

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2674 kWh

3290 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

226 %

168 %

Prated

11.52 kW

10.57 kW

SCOP

5.85

4.39

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.97 kW

6.40 kW

COP Tj = -7°C

5.69

4.02

Cdh Tj = -7 °C

0.99

0.99

Pdh Tj = +2°C

4.24 kW

3.89 kW

COP Tj = +2°C

6.38

4.92

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

2.73 kW

2.50 kW

COP Tj = +7°C

5.79

4.88

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.78 kW

2.74 kW

COP Tj = 12°C

5.51

4.74

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4856 kWh

5928 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

36 dB(A)

36 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

219 %

162 %

Prated

11.52 kW

10.57 kW

SCOP

5.67

4.25

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.19 kW

9.35 kW

COP Tj = -7°C

4.66

3.23

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

6.20 kW

5.69 kW

COP Tj = +2°C

5.81

4.27

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

3.99 kW

3.66 kW

COP Tj = +7°C

6.39

5.06

Cdh Tj = +7 °C

0.99

0.99

Pdh Tj = 12°C

2.77 kW

2.73 kW

COP Tj = 12°C

5.67

4.67

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

11.52 kW

10.57 kW

COP Tj = Tbiv

4.39

2.96

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.52 kW

10.57 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.39

2.96

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4195 kWh

5134 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

12.24 kW

14.24 kW

El input

2.01 kW

3.84 kW

COP

6.08

3.71

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

295 %

214 %

Prated

12.24 kW

14.24 kW

SCOP

7.57

5.56

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

12.24 kW

14.24 kW

COP Tj = +2°C

6.08

3.71

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

7.87 kW

9.16 kW

COP Tj = +7°C

7.15

4.96

Cdh Tj = +7 °C

0.99

1.00

Pdh Tj = 12°C

3.50 kW

4.07 kW

COP Tj = 12°C

8.40

6.62

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2161 kWh

3425 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

300 %

223 %

Prated

12.24 kW

14.24 kW

SCOP

7.70

5.77

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

7.41 kW

8.62 kW

COP Tj = -7°C

7.43

5.28

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

4.51 kW

5.25 kW

COP Tj = +2°C

8.14

6.31

Cdh Tj = +2 °C

0.98

0.99

Pdh Tj = +7°C

3.71 kW

3.37 kW

COP Tj = +7°C

8.35

7.00

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

3.68 kW

3.66 kW

COP Tj = 12°C

7.96

6.72

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3917 kWh

6086 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

292 %

213 %

Prated

12.24 kW

14.24 kW

SCOP

7.51

5.52

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.83 kW

12.60 kW

COP Tj = -7°C

6.35

4.09

Cdh Tj = -7 °C

0.99

1.00

Pdh Tj = +2°C

6.59 kW

7.67 kW

COP Tj = +2°C

7.52

5.56

Cdh Tj = +2 °C

0.99

0.99

Pdh Tj = +7°C

4.24 kW

4.93 kW

COP Tj = +7°C

8.40

6.49

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

3.70 kW

3.65 kW

COP Tj = 12°C

8.22

6.57

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

12.24 kW

14.24 kW

COP Tj = Tbiv

6.08

3.71

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.24 kW

14.24 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

6.08

3.71

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

9 W

9 W

PSB

9 W

9 W

PCK

0 W

9 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3369 kWh

5331 kWh