Certificate holders

Subtype

Thermia Mega E S 230-3

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700328 / issue 2
Certification Body
RISE CERT
Subtype title
Thermia Mega E S 230-3
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R454B
Mass of Refrigerant

4,000 kg

Certification Date
17.06.2024
Testing basis
EN 14511:2022, EN 14825:2022, EN 12102:2022
Testing laboratory
RISE Research Institutes of Sweden
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Thermia Mega E S 230-3
Configure model
Model name
Thermia Mega E S 230-3
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

19.96 kW

18.65 kW

El input

4.24 kW

6.26 kW

COP

4.71

2.98

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

158 %

Prated

33.12 kW

31.67 kW

SCOP

5.46

4.14

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

33.12 kW

31.67 kW

COP Tj = +2°C

4.20

2.86

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

21.29 kW

20.36 kW

COP Tj = +7°C

5.18

3.73

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

11.86 kW

11.63 kW

COP Tj = 12°C

6.01

4.84

Cdh Tj = +12 °C

0.990

1.000

Pdh Tj = Tbiv

33.12 kW

31.67 kW

COP Tj = Tbiv

4.20

2.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

33.12 kW

31.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.20

2.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

8106 kWh

10211 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

216 %

165 %

Prated

33.12 kW

31.67 kW

SCOP

5.60

4.31

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

20.05 kW

19.17 kW

COP Tj = -7°C

5.35

3.94

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

12.20 kW

11.67 kW

COP Tj = +2°C

5.96

4.73

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

11.86 kW

11.68 kW

COP Tj = +7°C

6.06

4.98

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

11.85 kW

11.74 kW

COP Tj = 12°C

5.91

5.16

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

33.12 kW

31.67 kW

COP Tj = Tbiv

4.20

2.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

33.12 kW

31.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.20

2.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

14576 kWh

18097 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

47 dB(A)

47 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

158 %

Prated

33.12 kW

31.67 kW

SCOP

5.40

4.15

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

29.30 kW

28.02 kW

COP Tj = -7°C

4.40

3.07

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

17.83 kW

17.06 kW

COP Tj = +2°C

5.44

4.18

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

11.46 kW

10.96 kW

COP Tj = +7°C

5.99

4.82

Cdh Tj = +7 °C

0.990

1.000

Pdh Tj = 12°C

11.86 kW

11.69 kW

COP Tj = 12°C

6.03

5.01

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

33.12 kW

31.67 kW

COP Tj = Tbiv

4.20

2.86

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

33.12 kW

31.67 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.20

2.86

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

12666 kWh

15756 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

27.07 kW

24.90 kW

El input

4.22 kW

6.32 kW

COP

6.42

3.94

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

318 %

217 %

Prated

45.37 kW

42.88 kW

SCOP

8.16

5.63

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

45.37 kW

42.88 kW

COP Tj = +2°C

5.62

3.81

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

29.17 kW

27.56 kW

COP Tj = +7°C

7.60

4.95

Cdh Tj = +7 °C

1.000

1.000

Pdh Tj = 12°C

14.71 kW

14.51 kW

COP Tj = 12°C

9.29

6.76

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

45.37 kW

42.88 kW

COP Tj = Tbiv

5.62

3.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

45.37 kW

42.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.62

3.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

7426 kWh

10170 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

330 %

225 %

Prated

45.37 kW

42.88 kW

SCOP

8.46

5.83

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

27.46 kW

25.95 kW

COP Tj = -7°C

7.98

5.25

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

16.72 kW

15.80 kW

COP Tj = +2°C

9.21

6.42

Cdh Tj = +2 °C

0.990

1.000

Pdh Tj = +7°C

14.72 kW

14.56 kW

COP Tj = +7°C

9.39

6.97

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

14.67 kW

14.60 kW

COP Tj = 12°C

8.98

7.20

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

45.37 kW

42.88 kW

COP Tj = Tbiv

5.62

3.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

45.37 kW

42.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.62

3.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

13225 kWh

18132 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

313 %

216 %

Prated

45.37 kW

42.88 kW

SCOP

8.03

5.61

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

40.13 kW

37.93 kW

COP Tj = -7°C

6.09

4.13

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

24.43 kW

23.09 kW

COP Tj = +2°C

8.16

5.60

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

15.70 kW

14.84 kW

COP Tj = +7°C

9.13

6.58

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

14.71 kW

14.56 kW

COP Tj = 12°C

9.27

6.98

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

45.37 kW

42.88 kW

COP Tj = Tbiv

5.62

3.81

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

45.37 kW

42.88 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

5.62

3.81

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

65 °C

65 °C

Poff

12 W

12 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

11679 kWh

15789 kWh