4,000 kg
Brine/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
19.96 kW
18.65 kW
El input
4.24 kW
6.26 kW
COP
4.71
2.98
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210 %
158 %
Prated
33.12 kW
31.67 kW
SCOP
5.46
4.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
33.12 kW
31.67 kW
COP Tj = +2°C
4.20
2.86
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
21.29 kW
20.36 kW
COP Tj = +7°C
5.18
3.73
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
11.86 kW
11.63 kW
COP Tj = 12°C
6.01
4.84
Cdh Tj = +12 °C
0.990
1.000
Pdh Tj = Tbiv
33.12 kW
31.67 kW
COP Tj = Tbiv
4.20
2.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.12 kW
31.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.20
2.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
8106 kWh
10211 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
216 %
165 %
Prated
33.12 kW
31.67 kW
SCOP
5.60
4.31
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
20.05 kW
19.17 kW
COP Tj = -7°C
5.35
3.94
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
12.20 kW
11.67 kW
COP Tj = +2°C
5.96
4.73
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
11.86 kW
11.68 kW
COP Tj = +7°C
6.06
4.98
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
11.85 kW
11.74 kW
COP Tj = 12°C
5.91
5.16
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
33.12 kW
31.67 kW
COP Tj = Tbiv
4.20
2.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.12 kW
31.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.20
2.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
14576 kWh
18097 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
47 dB(A)
47 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
208 %
158 %
Prated
33.12 kW
31.67 kW
SCOP
5.40
4.15
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
29.30 kW
28.02 kW
COP Tj = -7°C
4.40
3.07
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
17.83 kW
17.06 kW
COP Tj = +2°C
5.44
4.18
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
11.46 kW
10.96 kW
COP Tj = +7°C
5.99
4.82
Cdh Tj = +7 °C
0.990
1.000
Pdh Tj = 12°C
11.86 kW
11.69 kW
COP Tj = 12°C
6.03
5.01
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
33.12 kW
31.67 kW
COP Tj = Tbiv
4.20
2.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.12 kW
31.67 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.20
2.86
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
12666 kWh
15756 kWh
Water/Water Heat Pump
Heating
EN 14511-4
Starting and operating test
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
27.07 kW
24.90 kW
El input
4.22 kW
6.32 kW
COP
6.42
3.94
Warmer Climate
EN 14825
Low temperature
Medium temperature
ηs
318 %
217 %
Prated
45.37 kW
42.88 kW
SCOP
8.16
5.63
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
45.37 kW
42.88 kW
COP Tj = +2°C
5.62
3.81
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
29.17 kW
27.56 kW
COP Tj = +7°C
7.60
4.95
Cdh Tj = +7 °C
1.000
1.000
Pdh Tj = 12°C
14.71 kW
14.51 kW
COP Tj = 12°C
9.29
6.76
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
45.37 kW
42.88 kW
COP Tj = Tbiv
5.62
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
45.37 kW
42.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.62
3.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
7426 kWh
10170 kWh
Colder Climate
EN 14825
Low temperature
Medium temperature
ηs
330 %
225 %
Prated
45.37 kW
42.88 kW
SCOP
8.46
5.83
Tbiv
-22 °C
-22 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
27.46 kW
25.95 kW
COP Tj = -7°C
7.98
5.25
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
16.72 kW
15.80 kW
COP Tj = +2°C
9.21
6.42
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
14.72 kW
14.56 kW
COP Tj = +7°C
9.39
6.97
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
14.67 kW
14.60 kW
COP Tj = 12°C
8.98
7.20
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
45.37 kW
42.88 kW
COP Tj = Tbiv
5.62
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
45.37 kW
42.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.62
3.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
13225 kWh
18132 kWh
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
313 %
216 %
Prated
45.37 kW
42.88 kW
SCOP
8.03
5.61
Tbiv
-10 °C
-10 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
40.13 kW
37.93 kW
COP Tj = -7°C
6.09
4.13
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
24.43 kW
23.09 kW
COP Tj = +2°C
8.16
5.60
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
15.70 kW
14.84 kW
COP Tj = +7°C
9.13
6.58
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
14.71 kW
14.56 kW
COP Tj = 12°C
9.27
6.98
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
45.37 kW
42.88 kW
COP Tj = Tbiv
5.62
3.81
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
45.37 kW
42.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
5.62
3.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
65 °C
65 °C
Poff
12 W
12 W
PTO
12 W
12 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
11679 kWh
15789 kWh