Certificate holders

Subtype

Air Source Heat Pump- R290-50

Certificate Holder
PERFEXIM Sp. z o.o.
ul. Batorowska 60
62-081 Wysogotowo
Poland
Registration number
041-K103-05 / 01
Certification Body
BRE
Subtype title
Air Source Heat Pump- R290-50
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,800 kg

Certification Date
10.11.2026
Testing basis
HP KEYMARK certification scheme rules rev. no.15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PHA-50 (50-050-1756-003) BLN-050TC3
Configure model
Model name
PHA-50 (50-050-1756-003) BLN-050TC3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

48.19 kW

47.76 kW

El input

12.35 kW

17.24 kW

COP

3.90

2.77

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

82 dB(A)

80 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

156 %

130 %

Prated

35.40 kW

32.11 kW

SCOP

3.97

3.32

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

31.31 kW

28.41 kW

COP Tj = -7°C

2.96

2.12

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

19.35 kW

17.38 kW

COP Tj = +2°C

4.06

3.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

12.47 kW

11.30 kW

COP Tj = +7°C

4.51

4.39

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

14.91 kW

14.43 kW

COP Tj = 12°C

5.92

6.18

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

31.31 kW

28.41 kW

COP Tj = Tbiv

2.96

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

26.58 kW

26.21 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.53

1.89

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

108 W

108 W

PTO

118 W

118 W

PSB

108 W

108 W

PCK

150 W

150 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

8.82 kW

5.90 kW

Annual energy consumption Qhe

18407 kWh

19955 kWh