2,750 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
19.70 kW
17.60 kW
El input
5.26 kW
6.77 kW
COP
3.84
2.60
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
49 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
140 %
Prated
12.00 kW
12.50 kW
SCOP
4.82
3.57
Tbiv
-7 °C
-7 °C
TOL
-15 °C
-15 °C
Pdh Tj = -7°C
7.79 kW
8.14 kW
COP Tj = -7°C
3.54
2.73
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
6.31 kW
4.61 kW
COP Tj = +2°C
5.21
3.63
Cdh Tj = +2 °C
0.990
1.000
Pdh Tj = +7°C
6.48 kW
5.41 kW
COP Tj = +7°C
6.51
5.35
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
9.09 kW
6.95 kW
COP Tj = 12°C
7.97
7.18
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
7.79 kW
8.14 kW
COP Tj = Tbiv
3.54
2.73
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
9.15 kW
9.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.70
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
75 °C
75 °C
Poff
0 W
0 W
PTO
21 W
21 W
PSB
21 W
21 W
PCK
21 W
21 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
12.00 kW
12.50 kW
Annual energy consumption Qhe
6143 kWh
8623 kWh
Pdh Tj = -15°C (if TOL<-20°C)
9.15
9.19
COP Tj = -15°C (if TOL<-20°C)
2.17
1.70
Cdh Tj = -15 °C
1.000
1.000
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
49 dB(A)
46 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
140 %
Prated
13.00 kW
12.50 kW
SCOP
4.62
3.58
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
11.73 kW
11.60 kW
COP Tj = -7°C
2.41
1.86
Cdh Tj = -7 °C
1.000
1.000
Pdh Tj = +2°C
7.02 kW
7.11 kW
COP Tj = +2°C
4.73
3.63
Cdh Tj = +2 °C
1.000
1.000
Pdh Tj = +7°C
8.22 kW
5.54 kW
COP Tj = +7°C
6.24
4.74
Cdh Tj = +7 °C
0.990
0.990
Pdh Tj = 12°C
8.54 kW
6.94 kW
COP Tj = 12°C
7.94
6.85
Cdh Tj = +12 °C
0.990
0.990
Pdh Tj = Tbiv
11.73 kW
11.60 kW
COP Tj = Tbiv
2.41
1.86
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.82 kW
10.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.23
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.000
1.000
WTOL
75 °C
75 °C
Poff
0 W
0 W
PTO
21 W
21 W
PSB
21 W
21 W
PCK
21 W
21 W
Supplementary Heater: Type of energy input
n/a
n/a
Supplementary Heater: PSUP
2.20 kW
1.70 kW
Annual energy consumption Qhe
5820 kWh
7214 kWh