2,900 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
39.00 kW
39.00 kW
El input
9.75 kW
14.00 kW
COP
4.00
2.79
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
76 dB(A)
76 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
210.80 %
177.10 %
Prated
39.00 kW
39.00 kW
SCOP
5.35
4.50
Tbiv
7.00 °C
7.00 °C
TOL
2.00 °C
2.00 °C
Pdh Tj = +2°C
33.03 kW
32.88 kW
COP Tj = +2°C
2.44
2.15
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
24.06 kW
22.84 kW
COP Tj = +7°C
4.60
3.94
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
10.40 kW
10.91 kW
COP Tj = 12°C
8.32
6.37
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
24.06 kW
22.84 kW
COP Tj = Tbiv
4.60
3.94
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
33.03 kW
32.88 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.44
2.15
WTOL
85.00 °C
85.00 °C
Poff
14.00 W
14.00 W
PTO
13.00 W
13.00 W
PSB
14.00 W
14.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.98 kW
6.12 kW
Annual energy consumption Qhe
9746.00 kWh
11573.00 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
76 dB(A)
76 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
117 %
Prated
34.0 kW
33.5 kW
SCOP
3.84
3.00
Tbiv
-7.00 °C
-7.00 °C
TOL
-22.00 °C
-22.00 °C
Pdh Tj = -7°C
19.57 kW
19.91 kW
COP Tj = -7°C
3.14
2.43
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
12.29 kW
11.47 kW
COP Tj = +2°C
4.82
3.61
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
8.24 kW
8.08 kW
COP Tj = +7°C
7.02
5.29
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
6.49 kW
5.96 kW
COP Tj = 12°C
8.23
6.50
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
19.57 kW
19.91 kW
COP Tj = Tbiv
3.14
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
22.95 kW
23.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.96
1.54
WTOL
85.00 °C
85.00 °C
Poff
14.00 W
14.00 W
PTO
13.00 W
13.00 W
PSB
14.00 W
14.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
11.05 kW
10.31 kW
Annual energy consumption Qhe
21823.00 kWh
27514.00 kWh
Pdh Tj = -15°C (if TOL<-20°C)
26.69
26.18
COP Tj = -15°C (if TOL<-20°C)
2.31
1.83
Cdh Tj = -15 °C
0.9
0.9
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
76 dB(A)
76 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
165.1 %
132.5 %
Prated
39.0 kW
39.0 kW
SCOP
4.20
3.39
Tbiv
-5 °C
-5 °C
TOL
-10.00 °C
-10.00 °C
Pdh Tj = -7°C
31.37 kW
32.08 kW
COP Tj = -7°C
2.53
1.83
Cdh Tj = -7 °C
0.90
0.90
Pdh Tj = +2°C
20.72 kW
19.72 kW
COP Tj = +2°C
4.17
3.34
Cdh Tj = +2 °C
0.90
0.90
Pdh Tj = +7°C
12.92 kW
14.11 kW
COP Tj = +7°C
6.56
5.25
Cdh Tj = +7 °C
0.90
0.90
Pdh Tj = 12°C
6.53 kW
6.18 kW
COP Tj = 12°C
9.22
6.67
Cdh Tj = +12 °C
0.90
0.90
Pdh Tj = Tbiv
31.49 kW
32.25 kW
COP Tj = Tbiv
2.62
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
34.53 kW
33.78 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.98
1.77
WTOL
85.00 °C
85.00 °C
Poff
14.00 W
14.00 W
PTO
13.00 W
13.00 W
PSB
14.00 W
14.00 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
4.47 kW
5.22 kW
Annual energy consumption Qhe
19176 kWh
23781 kWh