3,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.04 kW
El input
3.76 kW
5.37 kW
COP
4.26
2.80
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
119 %
Prated
16.00 kW
14.00 kW
SCOP
3.80
3.06
Tbiv
-5 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
12.20 kW
COP Tj = -7°C
2.33
1.78
Pdh Tj = +2°C
8.60 kW
7.60 kW
COP Tj = +2°C
3.74
3.12
Pdh Tj = +7°C
5.70 kW
4.80 kW
COP Tj = +7°C
6.77
4.40
Pdh Tj = 12°C
6.50 kW
5.40 kW
COP Tj = 12°C
8.97
6.36
Pdh Tj = Tbiv
12.10 kW
12.20 kW
COP Tj = Tbiv
2.56
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
13.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.71
Cdh
1.00
1.00
WTOL
35 °C
55 °C
Poff
55 W
55 W
PTO
57 W
57 W
PSB
55 W
55 W
PCK
55 W
55 W
Supplementary Heater: Type of energy input
Electrical
Electrical
Supplementary Heater: PSUP
4.40 kW
0.90 kW
Annual energy consumption Qhe
8270 kWh
8970 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
86 %
COP
2.06
Heating up time
1:36 h:min
Standby power input
78.0 W
Reference hot water temperature
45.2 °C
Mixed water at 40°C
237 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.00 kW
15.04 kW
El input
3.76 kW
5.37 kW
COP
4.26
2.80
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
119 %
Prated
16.00 kW
14.00 kW
SCOP
3.80
3.06
Tbiv
-5 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.40 kW
12.20 kW
COP Tj = -7°C
2.33
1.78
Pdh Tj = +2°C
8.60 kW
7.60 kW
COP Tj = +2°C
3.74
3.12
Pdh Tj = +7°C
5.70 kW
4.80 kW
COP Tj = +7°C
6.77
4.40
Pdh Tj = 12°C
6.50 kW
5.40 kW
COP Tj = 12°C
8.97
6.36
Pdh Tj = Tbiv
12.10 kW
12.20 kW
COP Tj = Tbiv
2.56
1.78
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.70 kW
13.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.05
1.71
Cdh
1.00
1.00
WTOL
35 °C
55 °C
Poff
55 W
55 W
PTO
57 W
57 W
PSB
55 W
55 W
PCK
55 W
55 W
Supplementary Heater: Type of energy input
Electrical
Electrical
Supplementary Heater: PSUP
4.40 kW
0.90 kW
Annual energy consumption Qhe
8270 kWh
8970 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
86 %
COP
2.05
Heating up time
1:17 h:min
Standby power input
85.0 W
Reference hot water temperature
45.0 °C
Mixed water at 40°C
211 l