Certificate holders

Subtype

ROTEX HPSU MONOBLOC COMPACT 14KW (500L)

Certificate Holder
DAIKIN Europe N.V.
Zandvoordestraat 300
B-8400 Oostende
Belgium
Reg. No.
011-1W0273
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ROTEX HPSU MONOBLOC COMPACT 14KW (500L)
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410a
Mass Of Refrigerant

3,400 kg

Certification Date
n/a
Testing basis
n/a
Generate PDF Export model CSV
  • Number of models 2

Models

RBLQ014CW1 / RKHW16MX500C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

13.30 kW

El input

3.37 kW

4.91 kW

COP

4.30

2.71

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

15.00 kW

13.00 kW

SCOP

3.90

3.16

Tbiv

-5 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.70 kW

10.00 kW

COP Tj = -7°C

2.63

1.76

Pdh Tj = +2°C

7.70 kW

6.80 kW

COP Tj = +2°C

4.07

3.55

Pdh Tj = +7°C

5.10 kW

4.70 kW

COP Tj = +7°C

5.71

4.22

Pdh Tj = 12°C

5.20 kW

5.30 kW

COP Tj = 12°C

6.71

5.44

Pdh Tj = Tbiv

11.60 kW

11.00 kW

COP Tj = Tbiv

2.83

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.60 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.75

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

55 W

55 W

PTO

57 W

57 W

PSB

55 W

55 W

PCK

55 W

55 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.90 kW

0.60 kW

Annual energy consumption Qhe

7250 kWh

7900 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

86 %

COP

2.06

Heating up time

1:36 h:min

Standby power input

78.0 W

Reference hot water temperature

45.2 °C

Mixed water at 40°C

237 l

RBLQ014CW1 / RKHW16MXB500C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

14.50 kW

13.30 kW

El input

3.37 kW

4.91 kW

COP

4.30

2.71

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

Sound power level outdoor

64 dB(A)

64 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

153 %

123 %

Prated

15.00 kW

13.00 kW

SCOP

3.90

3.16

Tbiv

-5 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.70 kW

10.00 kW

COP Tj = -7°C

2.63

1.76

Pdh Tj = +2°C

7.70 kW

6.80 kW

COP Tj = +2°C

4.07

3.55

Pdh Tj = +7°C

5.10 kW

4.70 kW

COP Tj = +7°C

5.71

4.22

Pdh Tj = 12°C

5.20 kW

5.30 kW

COP Tj = 12°C

6.71

5.44

Pdh Tj = Tbiv

11.60 kW

11.00 kW

COP Tj = Tbiv

2.83

1.92

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.60 kW

12.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.75

Cdh

1.00

1.00

WTOL

35 °C

55 °C

Poff

55 W

55 W

PTO

57 W

57 W

PSB

55 W

55 W

PCK

55 W

55 W

Supplementary Heater: Type of energy input

Electrical

Electrical

Supplementary Heater: PSUP

1.90 kW

0.60 kW

Annual energy consumption Qhe

7250 kWh

7900 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

86 %

COP

2.05

Heating up time

1:17 h:min

Standby power input

85.0 W

Reference hot water temperature

45.0 °C

Mixed water at 40°C

211 l