3,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
13.30 kW
El input
3.37 kW
4.91 kW
COP
4.30
2.71
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
123 %
Prated
15.00 kW
13.00 kW
SCOP
3.90
3.16
Tbiv
-5 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.00 kW
COP Tj = -7°C
2.63
1.76
Pdh Tj = +2°C
7.70 kW
6.80 kW
COP Tj = +2°C
4.07
3.55
Pdh Tj = +7°C
5.10 kW
4.70 kW
COP Tj = +7°C
5.71
4.22
Pdh Tj = 12°C
5.20 kW
5.30 kW
COP Tj = 12°C
6.71
5.44
Pdh Tj = Tbiv
11.60 kW
11.00 kW
COP Tj = Tbiv
2.83
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
12.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.75
Cdh
1.00
1.00
WTOL
35 °C
55 °C
Poff
55 W
55 W
PTO
57 W
57 W
PSB
55 W
55 W
PCK
55 W
55 W
Supplementary Heater: Type of energy input
Electrical
Electrical
Supplementary Heater: PSUP
1.90 kW
0.60 kW
Annual energy consumption Qhe
7250 kWh
7900 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
86 %
COP
2.06
Heating up time
1:36 h:min
Standby power input
78.0 W
Reference hot water temperature
45.2 °C
Mixed water at 40°C
237 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.50 kW
13.30 kW
El input
3.37 kW
4.91 kW
COP
4.30
2.71
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
40 dB(A)
40 dB(A)
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
153 %
123 %
Prated
15.00 kW
13.00 kW
SCOP
3.90
3.16
Tbiv
-5 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.70 kW
10.00 kW
COP Tj = -7°C
2.63
1.76
Pdh Tj = +2°C
7.70 kW
6.80 kW
COP Tj = +2°C
4.07
3.55
Pdh Tj = +7°C
5.10 kW
4.70 kW
COP Tj = +7°C
5.71
4.22
Pdh Tj = 12°C
5.20 kW
5.30 kW
COP Tj = 12°C
6.71
5.44
Pdh Tj = Tbiv
11.60 kW
11.00 kW
COP Tj = Tbiv
2.83
1.92
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.60 kW
12.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.75
Cdh
1.00
1.00
WTOL
35 °C
55 °C
Poff
55 W
55 W
PTO
57 W
57 W
PSB
55 W
55 W
PCK
55 W
55 W
Supplementary Heater: Type of energy input
Electrical
Electrical
Supplementary Heater: PSUP
1.90 kW
0.60 kW
Annual energy consumption Qhe
7250 kWh
7900 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
86 %
COP
2.05
Heating up time
1:17 h:min
Standby power input
85.0 W
Reference hot water temperature
45.0 °C
Mixed water at 40°C
211 l