Certificate holders

Subtype

Matrix Zero MX290-08S/10S

Certificate Holder
INVENTOR A.G. SINGLE MEMBER ELECTRIC APPLIANCES S.A.
2 Thoukididou str. & 24th km National Road Athens - Lamia
14565 Agios Stefanos
Greece
Registration number
ICIM-PDC-000342
Certification Body
ICIM S.p.A.
Subtype title
Matrix Zero MX290-08S/10S
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,100 kg

Certification Date
29.07.2025
Testing basis
V12
Testing laboratory
Bureau Veritas Consumer Products Services (Guangzhou) Co., Ltd, Science City Branch
Generate PDF Export model CSV Download certificate
  • Number of models 2

Models

MX290-08S
Configure model
Model name
MX290-08S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.4 kW

7.8 kW

El input

1.68 kW

2.44 kW

COP

5.00

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259.00 %

184.00 %

Prated

8.2 kW

8.3 kW

SCOP

6.56

4.68

Tbiv

7.00 °C

7.00 °C

TOL

2.00 °C

2.00 °C

Pdh Tj = +2°C

8.20 kW

7.99 kW

COP Tj = +2°C

3.59

2.54

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.27 kW

5.36 kW

COP Tj = +7°C

6.03

4.15

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.46 kW

4.21 kW

COP Tj = 12°C

8.58

6.35

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.27 kW

5.36 kW

COP Tj = Tbiv

6.03

4.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.27 kW

7.99 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.54

WTOL

75.00 °C

75.00 °C

Poff

9.00 W

9.00 W

PTO

14.00 W

14.00 W

PSB

9 W

9 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.30 kW

Annual energy consumption Qhe

1669.00 kWh

2368.00 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

174 %

135 %

Prated

6.8 kW

7.0 kW

SCOP

4.44

3.46

Tbiv

-15.00 °C

-15.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

4.11 kW

4.49 kW

COP Tj = -7°C

3.97

2.87

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.18 kW

3.07 kW

COP Tj = +2°C

5.60

4.38

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.90 kW

3.67 kW

COP Tj = +7°C

6.46

5.58

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.43 kW

4.36 kW

COP Tj = 12°C

8.67

7.22

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.48 kW

5.69 kW

COP Tj = Tbiv

2.73

2.09

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.64 kW

5.08 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.09

1.54

WTOL

75.00 °C

75.00 °C

Poff

9.00 W

9.00 W

PTO

14 W

14 W

PSB

9.00 W

9.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.15 kW

1.92 kW

Annual energy consumption Qhe

3772.00 kWh

4992.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.48

5.69

COP Tj = -15°C (if TOL<-20°C)

2.73

2.09

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

204 %

149 %

Prated

8.00 kW

6.80 kW

SCOP

5.19

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.09 kW

5.97 kW

COP Tj = -7°C

3.06

2.37

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.53 kW

3.71 kW

COP Tj = +2°C

5.10

3.85

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.96 kW

3.62 kW

COP Tj = +7°C

7.47

5.12

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.51 kW

4.31 kW

COP Tj = 12°C

9.66

6.77

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.09 kW

5.97 kW

COP Tj = Tbiv

3.06

2.37

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.97 kW

6.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.56

2.08

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

 

 

WTOL

75 °C

75 °C

Poff

9 W

9 W

PTO

14 W

14 W

PSB

9 W

9 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.03 kW

0.34 kW

Annual energy consumption Qhe

3184 kWh

3676 kWh

MX290-10S
Configure model
Model name
MX290-10S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

10.0 kW

9.5 kW

El input

2.13 kW

3.11 kW

COP

4.70

3.05

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

281.00 %

188.00 %

Prated

8.6 kW

8.8 kW

SCOP

7.11

4.79

Tbiv

7.00 °C

7.00 °C

TOL

2.00 °C

2.00 °C

Pdh Tj = +2°C

8.60 kW

8.54 kW

COP Tj = +2°C

3.62

2.50

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

5.52 kW

5.68 kW

COP Tj = +7°C

6.26

4.20

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.61 kW

4.29 kW

COP Tj = 12°C

9.84

6.53

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

5.52 kW

5.68 kW

COP Tj = Tbiv

6.26

4.20

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.61 kW

8.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.62

2.50

WTOL

75.00 °C

75.00 °C

Poff

9.00 W

9.00 W

PTO

14.00 W

14.00 W

PSB

9 W

9 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.26 kW

Annual energy consumption Qhe

1614.00 kWh

2456.00 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

178 %

136 %

Prated

7.9 kW

8.0 kW

SCOP

4.54

3.49

Tbiv

-15.00 °C

-15.00 °C

TOL

-22.00 °C

-22.00 °C

Pdh Tj = -7°C

4.89 kW

4.86 kW

COP Tj = -7°C

3.74

2.90

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

3.07 kW

3.09 kW

COP Tj = +2°C

5.66

4.38

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.83 kW

3.76 kW

COP Tj = +7°C

7.63

5.64

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.46 kW

4.32 kW

COP Tj = 12°C

9.24

6.92

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

6.42 kW

6.55 kW

COP Tj = Tbiv

2.69

1.99

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.39 kW

5.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.08

1.57

WTOL

75.00 °C

75.00 °C

Poff

9.00 W

9.00 W

PTO

14 W

14 W

PSB

9.00 W

9.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.48 kW

2.20 kW

Annual energy consumption Qhe

4269.00 kWh

5659.00 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.42

6.55

COP Tj = -15°C (if TOL<-20°C)

2.69

1.99

Cdh Tj = -15 °C

0.9

0.9

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

61 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

149 %

Prated

9.2 kW

7.8 kW

SCOP

5.07

3.82

Tbiv

-7 °C

-7 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

8.11 kW

6.88 kW

COP Tj = -7°C

2.84

2.31

Cdh Tj = -7 °C

0.90

0.90

Pdh Tj = +2°C

5.10 kW

4.23 kW

COP Tj = +2°C

4.96

3.80

Cdh Tj = +2 °C

0.90

0.90

Pdh Tj = +7°C

3.96 kW

3.62 kW

COP Tj = +7°C

7.47

5.21

Cdh Tj = +7 °C

0.90

0.90

Pdh Tj = 12°C

4.48 kW

4.31 kW

COP Tj = 12°C

9.56

6.86

Cdh Tj = +12 °C

0.90

0.90

Pdh Tj = Tbiv

8.11 kW

6.88 kW

COP Tj = Tbiv

2.84

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.50 kW

7.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.99

WTOL

75.00 °C

75.00 °C

Poff

9.00 W

9.00 W

PTO

14.00 W

14.00 W

PSB

9.00 W

9.00 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.66 kW

0.35 kW

Annual energy consumption Qhe

3744 kWh

4215 kWh