Certificate holders

Subtype

ANGHP06

Certificate Holder
Argoclima S.p.A
Via Alfeno Varo, 35
25020 Alfianello (BS)
Italy
Registration number
047-A1000 / 1
Certification Body
UL International Italia S.r.l.
Subtype title
ANGHP06
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,500 kg

Certification Date
27.02.2025
Testing basis
Heat Pump Keymark scheme rules V15
Testing laboratory
Centro de Ensayos, Innovación y Servicios (CEIS), ES
Generate PDF Export model CSV
  • Number of models 1

Models

ANGHP06S
Configure model
Model name
ANGHP06S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.62 kW

6.13 kW

El input

1.47 kW

2.01 kW

COP

4.51

3.04

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

48 dB(A)

49 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

132 %

Prated

5.10 kW

4.60 kW

SCOP

4.75

3.37

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.38 kW

4.07 kW

COP Tj = -7°C

2.67

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.74 kW

2.42 kW

COP Tj = +2°C

4.94

3.29

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.70 kW

1.69 kW

COP Tj = +7°C

6.02

4.16

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.08 kW

0.96 kW

COP Tj = 12°C

7.65

4.90

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.38 kW

4.07 kW

COP Tj = Tbiv

2.67

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.07 kW

3.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.47

1.95

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.03 kW

1.03 kW

Annual energy consumption Qhe

2216 kWh

2816 kWh