0,500 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.62 kW
6.13 kW
El input
1.47 kW
2.01 kW
COP
4.51
3.04
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
48 dB(A)
49 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
132 %
Prated
5.10 kW
4.60 kW
SCOP
4.75
3.37
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.38 kW
4.07 kW
COP Tj = -7°C
2.67
2.40
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
2.74 kW
2.42 kW
COP Tj = +2°C
4.94
3.29
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
1.70 kW
1.69 kW
COP Tj = +7°C
6.02
4.16
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
1.08 kW
0.96 kW
COP Tj = 12°C
7.65
4.90
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
4.38 kW
4.07 kW
COP Tj = Tbiv
2.67
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.07 kW
3.58 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.47
1.95
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
6 W
6 W
PTO
6 W
6 W
PSB
6 W
6 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.03 kW
1.03 kW
Annual energy consumption Qhe
2216 kWh
2816 kWh