Certificate holders

Subtype

ANGHP16

Certificate Holder
Argoclima S.p.A
Via Alfeno Varo, 35
25020 Alfianello (BS)
Italy
Registration number
047-A1007
Certification Body
UL International Italia S.r.l.
Subtype title
ANGHP16
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,600 kg

Certification Date
27.02.2025
Testing basis
Heat Pump Keymark scheme rules V15
Testing laboratory
Centro de Ensayos, Innovación y Servicios (CEIS), ES
Generate PDF Export model CSV
  • Number of models 2

Models

ANGHP16S
Configure model
Model name
ANGHP16S
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.05 kW

15.40 kW

El input

3.73 kW

5.27 kW

COP

4.30

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

156 %

Prated

13.50 kW

12.50 kW

SCOP

5.15

3.97

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

10.54 kW

COP Tj = -7°C

2.92

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.04 kW

7.27 kW

COP Tj = +2°C

5.26

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.36 kW

4.67 kW

COP Tj = +7°C

7.21

5.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.86 kW

COP Tj = 12°C

10.43

8.47

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

10.54 kW

COP Tj = Tbiv

2.92

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.62 kW

9.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.88 kW

2.58 kW

Annual energy consumption Qhe

5421 kWh

6507 kWh

ANGHP16T
Configure model
Model name
ANGHP16T
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.05 kW

15.40 kW

El input

3.73 kW

5.27 kW

COP

4.30

2.92

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

156 %

Prated

13.50 kW

12.50 kW

SCOP

5.15

3.97

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.15 kW

10.54 kW

COP Tj = -7°C

2.92

2.14

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.04 kW

7.27 kW

COP Tj = +2°C

5.26

3.83

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.36 kW

4.67 kW

COP Tj = +7°C

7.21

5.74

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.87 kW

3.86 kW

COP Tj = 12°C

10.43

8.47

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

11.15 kW

10.54 kW

COP Tj = Tbiv

2.92

2.14

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.62 kW

9.92 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.60

1.98

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

6 W

6 W

PTO

6 W

6 W

PSB

6 W

6 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.88 kW

2.58 kW

Annual energy consumption Qhe

5421 kWh

6507 kWh