Certificate holders

Subtype

Thermia Calibra RXT 12

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700403 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermia Calibra RXT 12
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R290
Mass of Refrigerant

0,520 kg

Certification Date
25.06.2025
Testing basis
EN 14511:2022, EN 14825:2022, EN 16147:2017+A1:2022, EN 12102:2022
Testing laboratory
Universität Stuttgart, Prüfstelle HLK am Institut für Gebäudeenergetik, Thermotechnik und Energiespeicherung (IGTE), DE
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

Thermia Calibra RXT 12 Duo 230V
Configure model
Model name
Thermia Calibra RXT 12 Duo 230V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

10.23 kW

El input

1.27 kW

3.49 kW

COP

4.87

2.93

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

159 %

Prated

11.34 kW

10.23 kW

SCOP

5.39

4.18

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.34 kW

10.23 kW

COP Tj = +2°C

4.19

2.93

Cdh Tj = +2 °C

0.994

0.995

Pdh Tj = +7°C

7.29 kW

6.58 kW

COP Tj = +7°C

5.25

3.82

Cdh Tj = +7 °C

0.988

0.990

Pdh Tj = 12°C

3.24 kW

2.92 kW

COP Tj = 12°C

6.03

4.99

Cdh Tj = +12 °C

0.970

0.972

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2811 kWh

3269 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

163 %

Prated

11.34 kW

10.23 kW

SCOP

5.58

4.28

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.87 kW

6.19 kW

COP Tj = -7°C

5.46

4.00

Cdh Tj = -7 °C

0.986

0.989

Pdh Tj = +2°C

4.18 kW

3.77 kW

COP Tj = +2°C

5.96

4.70

Cdh Tj = +2 °C

0.977

0.979

Pdh Tj = +7°C

3.16 kW

2.72 kW

COP Tj = +7°C

6.03

4.85

Cdh Tj = +7 °C

0.968

0.970

Pdh Tj = 12°C

3.13 kW

2.72 kW

COP Tj = 12°C

5.80

4.86

Cdh Tj = +12 °C

0.969

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.43 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.944

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5007 kWh

5896 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

160 %

Prated

11.34 kW

10.23 kW

SCOP

5.40

4.19

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.03 kW

9.05 kW

COP Tj = -7°C

4.57

3.36

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

6.11 kW

5.51 kW

COP Tj = +2°C

5.53

4.30

Cdh Tj = +2 °C

0.984

0.987

Pdh Tj = +7°C

3.93 kW

3.54 kW

COP Tj = +7°C

6.01

4.71

Cdh Tj = +7 °C

0.976

0.978

Pdh Tj = 12°C

3.15 kW

2.70 kW

COP Tj = 12°C

5.94

4.77

Cdh Tj = +12 °C

0.968

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4337 kWh

5046 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.85 kW

13.46 kW

El input

2.93 kW

3.76 kW

COP

4.73

3.58

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

204 %

Prated

13.85 kW

13.46 kW

SCOP

6.76

5.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.85 kW

13.46 kW

COP Tj = +2°C

4.73

3.58

Cdh Tj = +2 °C

0.994

0.997

Pdh Tj = +7°C

8.90 kW

8.65 kW

COP Tj = +7°C

6.95

4.71

Cdh Tj = +7 °C

0.987

0.994

Pdh Tj = 12°C

3.96 kW

3.82 kW

COP Tj = 12°C

7.33

6.69

Cdh Tj = +12 °C

0.969

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2738 kWh

3394 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

274 %

218 %

Prated

13.85 kW

13.46 kW

SCOP

7.06

5.65

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.38 kW

8.15 kW

COP Tj = -7°C

7.20

5.08

Cdh Tj = -7 °C

0.986

0.993

Pdh Tj = +2°C

5.10 kW

4.96 kW

COP Tj = +2°C

7.47

6.36

Cdh Tj = +2 °C

0.976

0.986

Pdh Tj = +7°C

3.45 kW

3.82 kW

COP Tj = +7°C

7.33

6.80

Cdh Tj = +7 °C

0.964

0.979

Pdh Tj = 12°C

3.58 kW

3.82 kW

COP Tj = 12°C

7.34

6.84

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4834 kWh

5868 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

267 %

209 %

Prated

13.85 kW

13.46 kW

SCOP

6.88

5.42

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.25 kW

11.91 kW

COP Tj = -7°C

5.73

4.02

Cdh Tj = -7 °C

0.992

0.996

Pdh Tj = +2°C

7.46 kW

7.25 kW

COP Tj = +2°C

7.28

5.38

Cdh Tj = +2 °C

0.985

0.992

Pdh Tj = +7°C

4.79 kW

4.66 kW

COP Tj = +7°C

7.41

6.57

Cdh Tj = +7 °C

0.974

0.985

Pdh Tj = 12°C

3.52 kW

3.82 kW

COP Tj = 12°C

7.33

6.74

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4160 kWh

5134 kWh

Thermia Calibra RXT 12 Duo 400V
Configure model
Model name
Thermia Calibra RXT 12 Duo 400V
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

10.23 kW

El input

1.27 kW

3.49 kW

COP

4.87

2.93

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

159 %

Prated

11.34 kW

10.23 kW

SCOP

5.39

4.18

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.34 kW

10.23 kW

COP Tj = +2°C

4.19

2.93

Cdh Tj = +2 °C

0.994

0.995

Pdh Tj = +7°C

7.29 kW

6.58 kW

COP Tj = +7°C

5.25

3.82

Cdh Tj = +7 °C

0.988

0.990

Pdh Tj = 12°C

3.24 kW

2.92 kW

COP Tj = 12°C

6.03

4.99

Cdh Tj = +12 °C

0.970

0.972

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2811 kWh

3269 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

163 %

Prated

11.34 kW

10.23 kW

SCOP

5.58

4.28

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.87 kW

6.19 kW

COP Tj = -7°C

5.46

4.00

Cdh Tj = -7 °C

0.986

0.989

Pdh Tj = +2°C

4.18 kW

3.77 kW

COP Tj = +2°C

5.96

4.70

Cdh Tj = +2 °C

0.977

0.979

Pdh Tj = +7°C

3.16 kW

2.72 kW

COP Tj = +7°C

6.03

4.85

Cdh Tj = +7 °C

0.968

0.970

Pdh Tj = 12°C

3.13 kW

2.72 kW

COP Tj = 12°C

5.80

4.86

Cdh Tj = +12 °C

0.969

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.43 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.944

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5007 kWh

5896 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

160 %

Prated

11.34 kW

10.23 kW

SCOP

5.40

4.19

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.03 kW

9.05 kW

COP Tj = -7°C

4.57

3.36

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

6.11 kW

5.51 kW

COP Tj = +2°C

5.53

4.30

Cdh Tj = +2 °C

0.984

0.987

Pdh Tj = +7°C

3.93 kW

3.54 kW

COP Tj = +7°C

6.01

4.71

Cdh Tj = +7 °C

0.976

0.978

Pdh Tj = 12°C

3.15 kW

2.70 kW

COP Tj = 12°C

5.94

4.77

Cdh Tj = +12 °C

0.968

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4337 kWh

5046 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.85 kW

13.46 kW

El input

2.93 kW

3.76 kW

COP

4.73

3.58

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

204 %

Prated

13.85 kW

13.46 kW

SCOP

6.76

5.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.85 kW

13.46 kW

COP Tj = +2°C

4.73

3.58

Cdh Tj = +2 °C

0.994

0.997

Pdh Tj = +7°C

8.90 kW

8.65 kW

COP Tj = +7°C

6.95

4.71

Cdh Tj = +7 °C

0.987

0.994

Pdh Tj = 12°C

3.96 kW

3.82 kW

COP Tj = 12°C

7.33

6.69

Cdh Tj = +12 °C

0.969

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2738 kWh

3394 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

274 %

218 %

Prated

13.85 kW

13.46 kW

SCOP

7.06

5.65

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.38 kW

8.15 kW

COP Tj = -7°C

7.20

5.08

Cdh Tj = -7 °C

0.986

0.993

Pdh Tj = +2°C

5.10 kW

4.96 kW

COP Tj = +2°C

7.47

6.36

Cdh Tj = +2 °C

0.976

0.986

Pdh Tj = +7°C

3.45 kW

3.82 kW

COP Tj = +7°C

7.33

6.80

Cdh Tj = +7 °C

0.964

0.979

Pdh Tj = 12°C

3.58 kW

3.82 kW

COP Tj = 12°C

7.34

6.84

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4834 kWh

5868 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

267 %

209 %

Prated

13.85 kW

13.46 kW

SCOP

6.88

5.42

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.25 kW

11.91 kW

COP Tj = -7°C

5.73

4.02

Cdh Tj = -7 °C

0.992

0.996

Pdh Tj = +2°C

7.46 kW

7.25 kW

COP Tj = +2°C

7.28

5.38

Cdh Tj = +2 °C

0.985

0.992

Pdh Tj = +7°C

4.79 kW

4.66 kW

COP Tj = +7°C

7.41

6.57

Cdh Tj = +7 °C

0.974

0.985

Pdh Tj = 12°C

3.52 kW

3.82 kW

COP Tj = 12°C

7.33

6.74

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4160 kWh

5134 kWh

Thermia Calibra RXT 12 400V
Configure model
Model name
Thermia Calibra RXT 12 400V
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

10.23 kW

El input

1.27 kW

3.49 kW

COP

4.87

2.93

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

159 %

Prated

11.34 kW

10.23 kW

SCOP

5.39

4.18

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.34 kW

10.23 kW

COP Tj = +2°C

4.19

2.93

Cdh Tj = +2 °C

0.994

0.995

Pdh Tj = +7°C

7.29 kW

6.58 kW

COP Tj = +7°C

5.25

3.82

Cdh Tj = +7 °C

0.988

0.990

Pdh Tj = 12°C

3.24 kW

2.92 kW

COP Tj = 12°C

6.03

4.99

Cdh Tj = +12 °C

0.970

0.972

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2811 kWh

3269 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

163 %

Prated

11.34 kW

10.23 kW

SCOP

5.58

4.28

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.87 kW

6.19 kW

COP Tj = -7°C

5.46

4.00

Cdh Tj = -7 °C

0.986

0.989

Pdh Tj = +2°C

4.18 kW

3.77 kW

COP Tj = +2°C

5.96

4.70

Cdh Tj = +2 °C

0.977

0.979

Pdh Tj = +7°C

3.16 kW

2.72 kW

COP Tj = +7°C

6.03

4.85

Cdh Tj = +7 °C

0.968

0.970

Pdh Tj = 12°C

3.13 kW

2.72 kW

COP Tj = 12°C

5.80

4.86

Cdh Tj = +12 °C

0.969

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.43 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.944

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5007 kWh

5896 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

160 %

Prated

11.34 kW

10.23 kW

SCOP

5.40

4.19

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.03 kW

9.05 kW

COP Tj = -7°C

4.57

3.36

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

6.11 kW

5.51 kW

COP Tj = +2°C

5.53

4.30

Cdh Tj = +2 °C

0.984

0.987

Pdh Tj = +7°C

3.93 kW

3.54 kW

COP Tj = +7°C

6.01

4.71

Cdh Tj = +7 °C

0.976

0.978

Pdh Tj = 12°C

3.15 kW

2.70 kW

COP Tj = 12°C

5.94

4.77

Cdh Tj = +12 °C

0.968

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4337 kWh

5046 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.85 kW

13.46 kW

El input

2.93 kW

3.76 kW

COP

4.73

3.58

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

204 %

Prated

13.85 kW

13.46 kW

SCOP

6.76

5.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.85 kW

13.46 kW

COP Tj = +2°C

4.73

3.58

Cdh Tj = +2 °C

0.994

0.997

Pdh Tj = +7°C

8.90 kW

8.65 kW

COP Tj = +7°C

6.95

4.71

Cdh Tj = +7 °C

0.987

0.994

Pdh Tj = 12°C

3.96 kW

3.82 kW

COP Tj = 12°C

7.33

6.69

Cdh Tj = +12 °C

0.969

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2738 kWh

3394 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

274 %

218 %

Prated

13.85 kW

13.46 kW

SCOP

7.06

5.65

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.38 kW

8.15 kW

COP Tj = -7°C

7.20

5.08

Cdh Tj = -7 °C

0.986

0.993

Pdh Tj = +2°C

5.10 kW

4.96 kW

COP Tj = +2°C

7.47

6.36

Cdh Tj = +2 °C

0.976

0.986

Pdh Tj = +7°C

3.45 kW

3.82 kW

COP Tj = +7°C

7.33

6.80

Cdh Tj = +7 °C

0.964

0.979

Pdh Tj = 12°C

3.58 kW

3.82 kW

COP Tj = 12°C

7.34

6.84

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4834 kWh

5868 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

267 %

209 %

Prated

13.85 kW

13.46 kW

SCOP

6.88

5.42

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.25 kW

11.91 kW

COP Tj = -7°C

5.73

4.02

Cdh Tj = -7 °C

0.992

0.996

Pdh Tj = +2°C

7.46 kW

7.25 kW

COP Tj = +2°C

7.28

5.38

Cdh Tj = +2 °C

0.985

0.992

Pdh Tj = +7°C

4.79 kW

4.66 kW

COP Tj = +7°C

7.41

6.57

Cdh Tj = +7 °C

0.974

0.985

Pdh Tj = 12°C

3.52 kW

3.82 kW

COP Tj = 12°C

7.33

6.74

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4160 kWh

5134 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Thermia Calibra RXT 12 230V
Configure model
Model name
Thermia Calibra RXT 12 230V
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

10.23 kW

El input

1.27 kW

3.49 kW

COP

4.87

2.93

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

159 %

Prated

11.34 kW

10.23 kW

SCOP

5.39

4.18

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

11.34 kW

10.23 kW

COP Tj = +2°C

4.19

2.93

Cdh Tj = +2 °C

0.994

0.995

Pdh Tj = +7°C

7.29 kW

6.58 kW

COP Tj = +7°C

5.25

3.82

Cdh Tj = +7 °C

0.988

0.990

Pdh Tj = 12°C

3.24 kW

2.92 kW

COP Tj = 12°C

6.03

4.99

Cdh Tj = +12 °C

0.970

0.972

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2811 kWh

3269 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

215 %

163 %

Prated

11.34 kW

10.23 kW

SCOP

5.58

4.28

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.87 kW

6.19 kW

COP Tj = -7°C

5.46

4.00

Cdh Tj = -7 °C

0.986

0.989

Pdh Tj = +2°C

4.18 kW

3.77 kW

COP Tj = +2°C

5.96

4.70

Cdh Tj = +2 °C

0.977

0.979

Pdh Tj = +7°C

3.16 kW

2.72 kW

COP Tj = +7°C

6.03

4.85

Cdh Tj = +7 °C

0.968

0.970

Pdh Tj = 12°C

3.13 kW

2.72 kW

COP Tj = 12°C

5.80

4.86

Cdh Tj = +12 °C

0.969

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.43 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.944

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

5007 kWh

5896 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

40 dB(A)

40 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

208 %

160 %

Prated

11.34 kW

10.23 kW

SCOP

5.40

4.19

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.03 kW

9.05 kW

COP Tj = -7°C

4.57

3.36

Cdh Tj = -7 °C

0.992

0.994

Pdh Tj = +2°C

6.11 kW

5.51 kW

COP Tj = +2°C

5.53

4.30

Cdh Tj = +2 °C

0.984

0.987

Pdh Tj = +7°C

3.93 kW

3.54 kW

COP Tj = +7°C

6.01

4.71

Cdh Tj = +7 °C

0.976

0.978

Pdh Tj = 12°C

3.15 kW

2.70 kW

COP Tj = 12°C

5.94

4.77

Cdh Tj = +12 °C

0.968

0.970

Pdh Tj = Tbiv

11.34 kW

10.23 kW

COP Tj = Tbiv

4.19

2.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.34 kW

10.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.19

2.93

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.995

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4337 kWh

5046 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

13.85 kW

13.46 kW

El input

2.93 kW

3.76 kW

COP

4.73

3.58

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

204 %

Prated

13.85 kW

13.46 kW

SCOP

6.76

5.30

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

13.85 kW

13.46 kW

COP Tj = +2°C

4.73

3.58

Cdh Tj = +2 °C

0.994

0.997

Pdh Tj = +7°C

8.90 kW

8.65 kW

COP Tj = +7°C

6.95

4.71

Cdh Tj = +7 °C

0.987

0.994

Pdh Tj = 12°C

3.96 kW

3.82 kW

COP Tj = 12°C

7.33

6.69

Cdh Tj = +12 °C

0.969

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2738 kWh

3394 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

274 %

218 %

Prated

13.85 kW

13.46 kW

SCOP

7.06

5.65

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

8.38 kW

8.15 kW

COP Tj = -7°C

7.20

5.08

Cdh Tj = -7 °C

0.986

0.993

Pdh Tj = +2°C

5.10 kW

4.96 kW

COP Tj = +2°C

7.47

6.36

Cdh Tj = +2 °C

0.976

0.986

Pdh Tj = +7°C

3.45 kW

3.82 kW

COP Tj = +7°C

7.33

6.80

Cdh Tj = +7 °C

0.964

0.979

Pdh Tj = 12°C

3.58 kW

3.82 kW

COP Tj = 12°C

7.34

6.84

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4834 kWh

5868 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

267 %

209 %

Prated

13.85 kW

13.46 kW

SCOP

6.88

5.42

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

12.25 kW

11.91 kW

COP Tj = -7°C

5.73

4.02

Cdh Tj = -7 °C

0.992

0.996

Pdh Tj = +2°C

7.46 kW

7.25 kW

COP Tj = +2°C

7.28

5.38

Cdh Tj = +2 °C

0.985

0.992

Pdh Tj = +7°C

4.79 kW

4.66 kW

COP Tj = +7°C

7.41

6.57

Cdh Tj = +7 °C

0.974

0.985

Pdh Tj = 12°C

3.52 kW

3.82 kW

COP Tj = 12°C

7.33

6.74

Cdh Tj = +12 °C

0.965

0.979

Pdh Tj = Tbiv

13.85 kW

13.46 kW

COP Tj = Tbiv

4.73

3.58

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.85 kW

13.46 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.73

3.58

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.994

0.997

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

4160 kWh

5134 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

123 %

COP

3.06

Heating up time

1:55 h:min

Standby power input

34.0 W

Reference hot water temperature

50.9 °C

Mixed water at 40°C

227 l