Certificate holders

Subtype

Thermia Calibra RXT 7

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
012-C700402 / Issue 1
Certification Body
RISE CERT
Subtype title
Thermia Calibra RXT 7
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R290
Mass of Refrigerant

0,330 kg

Certification Date
25.06.2025
Testing basis
EN 14511:2022, EN 14825:2022, EN 16147:2017+A1:2022, EN 12102:2022
Testing laboratory
Universität Stuttgart, Prüfstelle HLK am Institut für Gebäudeenergetik, Thermotechnik und Energiespeicherung (IGTE), DE
Generate PDF Export model CSV Download certificate
  • Number of models 3

Models

Thermia Calibra RXT 7 Duo
Configure model
Model name
Thermia Calibra RXT 7 Duo
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

Thermia Calibra RXT 7 "Profile XL"
Configure model
Model name
Thermia Calibra RXT 7 "Profile XL"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Thermia Calibra RXT 7 "Profile M"
Configure model
Model name
Thermia Calibra RXT 7 "Profile M"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

78 %

COP

1.94

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

223 l

Colder Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

78 %

COP

1.94

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

223 l

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

78 %

COP

1.94

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

223 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

78 %

COP

1.94

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

223 l

Colder Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

78 %

COP

1.94

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

223 l

Average Climate

EN 16147

Declared load profile

M

Efficiency ηDHW

78 %

COP

1.94

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

50.0 °C

Mixed water at 40°C

223 l