Certificate holders

Subtype

Ultraheat series R290 50kW

Certificate Holder
Guangdong Luckingstar New Energy CO., LTD.
No.255 Hexiang East Rd, C area, Heshan Industrial Zone, Heshan City
Guangdong
China
Registration number
011-1W1068
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Ultraheat series R290 50kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

4,000 kg

Certification Date
03.07.2025
Testing basis
HP KEYMARK certification scheme rules rev. 14
Testing laboratory
Intertek Testing Services Shenzhen LTD. Guangzhou Branch, CN
Generate PDF Export model CSV
  • Number of models 1

Models

LWH-F50VSN9H
Configure model
Model name
LWH-F50VSN9H
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

50.00 kW

50.00 kW

El input

11.56 kW

16.56 kW

COP

4.31

3.03

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

66 dB(A)

66 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

141 %

Prated

50.00 kW

50.00 kW

SCOP

4.69

3.59

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

44.57 kW

44.42 kW

COP Tj = -7°C

2.93

2.12

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

27.69 kW

27.55 kW

COP Tj = +2°C

4.64

3.48

Cdh Tj = +2 °C

0.993

0.995

Pdh Tj = +7°C

18.08 kW

17.92 kW

COP Tj = +7°C

5.86

4.88

Cdh Tj = +7 °C

0.987

0.989

Pdh Tj = 12°C

21.31 kW

19.56 kW

COP Tj = 12°C

8.62

6.56

Cdh Tj = +12 °C

0.984

0.987

Pdh Tj = Tbiv

44.57 kW

44.42 kW

COP Tj = Tbiv

2.93

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

38.45 kW

36.51 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.55

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.997

0.998

WTOL

75 °C

75 °C

Poff

25 W

25 W

PTO

39 W

39 W

PSB

25 W

25 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

11.60 kW

13.50 kW

Annual energy consumption Qhe

22028 kWh

28753 kWh