3,000 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
31.39 kW
30.13 kW
El input
7.03 kW
10.46 kW
COP
4.47
2.88
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
68 dB(A)
69 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
134 %
Prated
31.08 kW
30.01 kW
SCOP
4.58
3.42
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
27.49 kW
26.54 kW
COP Tj = -7°C
2.89
2.33
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
17.07 kW
16.18 kW
COP Tj = +2°C
4.50
3.31
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
11.87 kW
10.95 kW
COP Tj = +7°C
6.12
4.30
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
10.51 kW
11.14 kW
COP Tj = 12°C
6.91
5.84
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
27.49 kW
26.54 kW
COP Tj = Tbiv
2.89
2.33
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
31.39 kW
30.38 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.68
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
173 W
173 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
14015 kWh
18113 kWh