Certificate holders

Subtype

Aquarea T-CAP 16 kW (M Series) + TD30

Certificate Holder
Panasonic Marketing Europe GmbH
Hagenauer Strasse 43, Wiesbaden
65203 Wiesbaden
Germany
Registration number
011-1W1057
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Aquarea T-CAP 16 kW (M Series) + TD30
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,770 kg

Certification Date
03.07.2025
Testing basis
HP KEYMARK certification scheme rules rev. 14
Testing laboratory
Danish Technological Institute (DTI), DK
Generate PDF Export model CSV
  • Number of models 3

Models

WH-WXG16ME8 + PAW-TD30C1E5HI-1
Configure model
Model name
WH-WXG16ME8 + PAW-TD30C1E5HI-1
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.27 kW

5.00 kW

COP

4.89

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.49 kW

1.71 kW

Cooling capacity

9.00

9.00

EER

3.61

5.26

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

9.00 kW

9.00 kW

SEER

4.80

7.62

Pdc Tj = 35°C

9.00 kW

9.00 kW

EER Tj = 35°C

3.61

5.26

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

6.63 kW

7.45 kW

EER Tj = 30°C

4.40

7.05

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

6.46 kW

7.28 kW

EER Tj = 25°C

5.17

8.74

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

6.78 kW

7.15 kW

EER Tj = 20°C

6.12

10.10

Cdc Tj = 20 °C

0.990

0.990

Poff

11 W

11 W

PTO

7 W

7 W

PSB

11 W

11 W

PCK

0 W

0 W

Annual energy consumption Qce

657 kWh

414 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

175 %

Prated

16.00 kW

16.00 kW

SCOP

6.08

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.00 kW

16.00 kW

COP Tj = +2°C

3.00

2.42

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.30 kW

10.30 kW

COP Tj = +7°C

5.37

4.13

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.70 kW

5.60 kW

COP Tj = 12°C

7.67

5.25

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

3.00

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

3517 kWh

4801 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

133 %

Prated

16.00 kW

16.00 kW

SCOP

4.33

3.40

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.70 kW

9.70 kW

COP Tj = -7°C

3.60

2.95

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.90 kW

5.90 kW

COP Tj = +2°C

4.96

3.82

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.00 kW

5.00 kW

COP Tj = +7°C

6.18

4.89

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.60 kW

5.70 kW

COP Tj = 12°C

7.49

5.84

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.03

1.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

9101 kWh

11613 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.10

13.10

COP Tj = -15°C (if TOL<-20°C)

2.96

2.19

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

145 %

Prated

16.00 kW

16.00 kW

SCOP

4.75

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.20 kW

COP Tj = -7°C

2.88

2.22

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.60 kW

8.60 kW

COP Tj = +2°C

4.59

3.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.50 kW

COP Tj = +7°C

6.33

4.81

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.80 kW

5.50 kW

COP Tj = 12°C

7.83

5.78

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.72

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

6966 kWh

8935 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.40

Heating up time

0:45 h:min

Standby power input

50.0 W

Reference hot water temperature

56.3 °C

Mixed water at 40°C

437 l

WH-CME8 / WH-WXG16ME8 + PAW-TD30C1E5HI-1
Configure model
Model name
WH-CME8 / WH-WXG16ME8 + PAW-TD30C1E5HI-1
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.27 kW

5.00 kW

COP

4.89

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.49 kW

1.71 kW

Cooling capacity

9.00

9.00

EER

3.61

5.26

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

9.00 kW

9.00 kW

SEER

4.80

7.62

Pdc Tj = 35°C

9.00 kW

9.00 kW

EER Tj = 35°C

3.61

5.26

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

6.63 kW

7.45 kW

EER Tj = 30°C

4.40

7.05

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

6.46 kW

7.28 kW

EER Tj = 25°C

5.17

8.74

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

6.78 kW

7.15 kW

EER Tj = 20°C

6.12

10.10

Cdc Tj = 20 °C

0.990

0.990

Poff

11 W

11 W

PTO

7 W

7 W

PSB

11 W

11 W

PCK

0 W

0 W

Annual energy consumption Qce

657 kWh

414 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

175 %

Prated

16.00 kW

16.00 kW

SCOP

6.08

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.00 kW

16.00 kW

COP Tj = +2°C

3.00

2.42

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.30 kW

10.30 kW

COP Tj = +7°C

5.37

4.13

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.70 kW

5.60 kW

COP Tj = 12°C

7.67

5.25

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

3.00

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

3517 kWh

4801 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

133 %

Prated

16.00 kW

16.00 kW

SCOP

4.33

3.40

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.70 kW

9.70 kW

COP Tj = -7°C

3.60

2.95

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.90 kW

5.90 kW

COP Tj = +2°C

4.96

3.82

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.00 kW

5.00 kW

COP Tj = +7°C

6.18

4.89

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.60 kW

5.70 kW

COP Tj = 12°C

7.49

5.84

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.03

1.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

9101 kWh

11613 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.10

13.10

COP Tj = -15°C (if TOL<-20°C)

2.96

2.19

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

145 %

Prated

16.00 kW

16.00 kW

SCOP

4.75

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.20 kW

COP Tj = -7°C

2.88

2.22

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.60 kW

8.60 kW

COP Tj = +2°C

4.59

3.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.50 kW

COP Tj = +7°C

6.33

4.81

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.80 kW

5.50 kW

COP Tj = 12°C

7.83

5.78

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.72

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

6966 kWh

8935 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.40

Heating up time

0:45 h:min

Standby power input

50.0 W

Reference hot water temperature

56.3 °C

Mixed water at 40°C

437 l

WH-SDC0316M9E8 / WH-WXG16ME8 + PAW-TD30C1E5HI-1
Configure model
Model name
WH-SDC0316M9E8 / WH-WXG16ME8 + PAW-TD30C1E5HI-1
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.27 kW

5.00 kW

COP

4.89

3.20

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.49 kW

1.71 kW

Cooling capacity

9.00

9.00

EER

3.61

5.26

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

9.00 kW

9.00 kW

SEER

4.80

7.62

Pdc Tj = 35°C

9.00 kW

9.00 kW

EER Tj = 35°C

3.61

5.26

Cdc Tj = 35 °C

1.000

1.000

Pdc Tj = 30°C

6.63 kW

7.45 kW

EER Tj = 30°C

4.40

7.05

Cdc Tj = 30 °C

1.000

1.000

Pdc Tj = 25°C

6.46 kW

7.28 kW

EER Tj = 25°C

5.17

8.74

Cdc Tj = 25 °C

0.990

0.990

Pdc Tj = 20°C

6.78 kW

7.15 kW

EER Tj = 20°C

6.12

10.10

Cdc Tj = 20 °C

0.990

0.990

Poff

11 W

11 W

PTO

7 W

7 W

PSB

11 W

11 W

PCK

0 W

0 W

Annual energy consumption Qce

657 kWh

414 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

175 %

Prated

16.00 kW

16.00 kW

SCOP

6.08

4.45

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

16.00 kW

16.00 kW

COP Tj = +2°C

3.00

2.42

Cdh Tj = +2 °C

1.000

1.000

Pdh Tj = +7°C

10.30 kW

10.30 kW

COP Tj = +7°C

5.37

4.13

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

5.70 kW

5.60 kW

COP Tj = 12°C

7.67

5.25

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

3.00

2.42

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.00

2.42

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

3517 kWh

4801 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

170 %

133 %

Prated

16.00 kW

16.00 kW

SCOP

4.33

3.40

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

9.70 kW

9.70 kW

COP Tj = -7°C

3.60

2.95

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

5.90 kW

5.90 kW

COP Tj = +2°C

4.96

3.82

Cdh Tj = +2 °C

0.980

0.990

Pdh Tj = +7°C

5.00 kW

5.00 kW

COP Tj = +7°C

6.18

4.89

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.60 kW

5.70 kW

COP Tj = 12°C

7.49

5.84

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.03

1.50

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.03

1.50

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

9101 kWh

11613 kWh

Pdh Tj = -15°C (if TOL<-20°C)

13.10

13.10

COP Tj = -15°C (if TOL<-20°C)

2.96

2.19

Cdh Tj = -15 °C

1.000

1.000

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

57 dB(A)

57 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

187 %

145 %

Prated

16.00 kW

16.00 kW

SCOP

4.75

3.70

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

14.20 kW

14.20 kW

COP Tj = -7°C

2.88

2.22

Cdh Tj = -7 °C

1.000

1.000

Pdh Tj = +2°C

8.60 kW

8.60 kW

COP Tj = +2°C

4.59

3.66

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.50 kW

5.50 kW

COP Tj = +7°C

6.33

4.81

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

5.80 kW

5.50 kW

COP Tj = 12°C

7.83

5.78

Cdh Tj = +12 °C

0.980

0.980

Pdh Tj = Tbiv

16.00 kW

16.00 kW

COP Tj = Tbiv

2.72

2.04

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

16.00 kW

16.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.72

2.04

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

1.000

1.000

WTOL

55 °C

55 °C

Poff

11 W

11 W

PTO

18 W

18 W

PSB

11 W

11 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

n/a

n/a

Annual energy consumption Qhe

6966 kWh

8935 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

96 %

COP

2.40

Heating up time

0:45 h:min

Standby power input

50.0 W

Reference hot water temperature

56.3 °C

Mixed water at 40°C

437 l