1,200 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.75 kW
11.98 kW
El input
2.56 kW
3.79 kW
COP
4.59
3.16
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
151 %
Prated
12.21 kW
12.09 kW
SCOP
4.82
3.85
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.80 kW
10.70 kW
COP Tj = -7°C
2.81
2.29
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.66 kW
6.82 kW
COP Tj = +2°C
4.73
3.79
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.24 kW
4.23 kW
COP Tj = +7°C
6.53
4.96
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.34 kW
4.22 kW
COP Tj = 12°C
8.87
7.45
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.80 kW
10.70 kW
COP Tj = Tbiv
2.81
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.40 kW
12.13 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.29
2.00
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
80 °C
80 °C
Poff
8 W
8 W
PTO
8 W
8 W
PSB
8 W
8 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
5233 kWh
6489 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
11.80 kW
11.99 kW
El input
2.44 kW
3.65 kW
COP
4.83
3.28
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
54 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
152 %
Prated
12.03 kW
12.22 kW
SCOP
4.83
3.86
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.64 kW
10.81 kW
COP Tj = -7°C
2.96
2.20
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.72 kW
6.81 kW
COP Tj = +2°C
4.78
3.85
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.20 kW
4.28 kW
COP Tj = +7°C
6.31
5.09
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
4.47 kW
4.36 kW
COP Tj = 12°C
8.43
7.19
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.64 kW
10.81 kW
COP Tj = Tbiv
2.96
2.20
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.00 kW
12.19 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.35
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
80 °C
80 °C
Poff
13 W
13 W
PTO
12 W
12 W
PSB
13 W
13 W
PCK
41 W
41 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.03 kW
0.03 kW
Annual energy consumption Qhe
5141 kWh
6537 kWh