1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
19.67 kW
19.96 kW
El input
4.45 kW
7.65 kW
COP
4.42
2.61
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
66 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
136 %
Prated
19.76 kW
17.23 kW
SCOP
4.71
3.49
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
17.48 kW
15.24 kW
COP Tj = -7°C
2.90
2.31
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
10.73 kW
9.41 kW
COP Tj = +2°C
4.69
3.45
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.35 kW
7.92 kW
COP Tj = +7°C
6.38
4.52
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
9.25 kW
9.12 kW
COP Tj = 12°C
7.87
5.93
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
17.48 kW
15.24 kW
COP Tj = Tbiv
2.90
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
18.76 kW
17.05 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.48
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
16 W
16 W
PTO
16 W
16 W
PSB
16 W
16 W
PCK
86 W
86 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.00 kW
0.19 kW
Annual energy consumption Qhe
8661 kWh
10215 kWh