Certificate holders

Subtype

TTF\TTC 7.1 comfort

Certificate Holder
tecalor GmbH
Lüchtringer Weg 3
37603 Holzminden
Germany
Registration number
012-C700386 / Issue 2
Certification Body
RISE CERT
Subtype title
TTF\TTC 7.1 comfort
Driving energy
Electricity
Heat Pump Type
Brine/Water and Water/Water
Refrigerant
R290
Mass of Refrigerant

0,330 kg

Certification Date
20.05.2025
Testing basis
EN 14511:2022, EN 14825:2022, EN 16147:2017+A1:2022, EN 12102:2022
Testing laboratory
Universität Stuttgart, Prüfstelle HLK am Institut für Gebäudeenergetik, Thermotechnik und Energiespeicherung (IGTE), DE
Generate PDF Export model CSV Download certificate
  • Number of models 4

Models

TTF 7.1 comfort
Configure model
Model name
TTF 7.1 comfort
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

TTF 7.1 230 comfort
Configure model
Model name
TTF 7.1 230 comfort
Application
Heating (medium temp)
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

TTC 7.1 comfort "Profile XL"
Configure model
Model name
TTC 7.1 comfort "Profile XL"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

TTC 7.1 230 comfort "Profile XL"
Configure model
Model name
TTC 7.1 230 comfort "Profile XL"
Application
Heating + DHW + low temp
Units
Indoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz
Off-peak product
n/a

Brine/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

3.36 kW

6.41 kW

El input

0.73 kW

2.28 kW

COP

4.62

2.82

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.28

4.11

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

7.02 kW

6.41 kW

COP Tj = +2°C

4.22

2.82

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

4.51 kW

4.12 kW

COP Tj = +7°C

5.22

3.65

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.01 kW

1.83 kW

COP Tj = 12°C

5.98

5.21

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1777 kWh

2083 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

210 %

157 %

Prated

7.02 kW

6.41 kW

SCOP

5.46

4.13

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

4.25 kW

3.88 kW

COP Tj = -7°C

5.33

3.82

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

2.59 kW

2.36 kW

COP Tj = +2°C

5.88

4.36

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

1.66 kW

1.95 kW

COP Tj = +7°C

5.93

5.63

Cdh Tj = +7 °C

0.940

0.950

Pdh Tj = 12°C

1.70 kW

1.95 kW

COP Tj = 12°C

5.50

5.69

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

3168 kWh

3828 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

38 dB(A)

38 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

200 %

154 %

Prated

7.02 kW

6.41 kW

SCOP

5.21

4.05

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.21 kW

5.67 kW

COP Tj = -7°C

4.57

3.10

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

3.78 kW

3.45 kW

COP Tj = +2°C

5.34

4.09

Cdh Tj = +2 °C

0.980

0.980

Pdh Tj = +7°C

2.43 kW

2.22 kW

COP Tj = +7°C

5.84

4.73

Cdh Tj = +7 °C

0.960

0.970

Pdh Tj = 12°C

1.72 kW

1.95 kW

COP Tj = 12°C

5.70

5.61

Cdh Tj = +12 °C

0.940

0.950

Pdh Tj = Tbiv

7.02 kW

6.41 kW

COP Tj = Tbiv

4.22

2.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.02 kW

6.41 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.22

2.82

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2785 kWh

3271 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3,24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Water/Water Heat Pump

Heating

EN 14511-4

Starting and operating test

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.19 kW

7.66 kW

El input

0.68 kW

2.26 kW

COP

6.16

3.39

Warmer Climate

EN 14825

Low temperature

Medium temperature

ηs

262 %

199 %

Prated

8.52 kW

7.66 kW

SCOP

6.74

5.16

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.52 kW

7.66 kW

COP Tj = +2°C

4.94

3.39

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

5.48 kW

4.92 kW

COP Tj = +7°C

6.63

4.62

Cdh Tj = +7 °C

0.980

0.980

Pdh Tj = 12°C

2.43 kW

2.19 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.950

0.950

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1689 kWh

1982 kWh

Colder Climate

EN 14825

Low temperature

Medium temperature

ηs

277 %

207 %

Prated

8.52 kW

7.66 kW

SCOP

7.12

5.38

Tbiv

-22 °C

-22 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.16 kW

4.64 kW

COP Tj = -7°C

6.91

4.90

Cdh Tj = -7 °C

0.980

0.980

Pdh Tj = +2°C

3.14 kW

2.82 kW

COP Tj = +2°C

7.80

5.98

Cdh Tj = +2 °C

0.960

0.970

Pdh Tj = +7°C

2.02 kW

1.81 kW

COP Tj = +7°C

7.73

6.93

Cdh Tj = +7 °C

0.930

0.940

Pdh Tj = 12°C

1.94 kW

1.92 kW

COP Tj = 12°C

7.61

6.48

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2952 kWh

3509 kWh

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

264 %

197 %

Prated

8.52 kW

7.66 kW

SCOP

6.79

5.11

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.54 kW

6.78 kW

COP Tj = -7°C

5.47

3.78

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

4.59 kW

4.12 kW

COP Tj = +2°C

7.08

5.21

Cdh Tj = +2 °C

0.970

0.980

Pdh Tj = +7°C

2.95 kW

2.65 kW

COP Tj = +7°C

7.80

6.25

Cdh Tj = +7 °C

0.950

0.960

Pdh Tj = 12°C

1.93 kW

1.91 kW

COP Tj = 12°C

7.69

6.38

Cdh Tj = +12 °C

0.930

0.940

Pdh Tj = Tbiv

8.52 kW

7.66 kW

COP Tj = Tbiv

4.94

3.39

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.52 kW

7.66 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

4.94

3.39

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

70 °C

70 °C

Poff

17 W

17 W

PTO

19 W

19 W

PSB

17 W

17 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

2593 kWh

3094 kWh

Domestic Hot Water (DHW)

Warmer Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Colder Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

128 %

COP

3.20

Heating up time

3:24 h:min

Standby power input

41.0 W

Reference hot water temperature

49.8 °C

Mixed water at 40°C

215 l