Certificate holders

Subtype

ADAPT MAX 10070

Certificate Holder
KRONOTERM d.o.o.
Trnava 5e
3303 Gomilsko
Slovenia
Registration number
011-1W1029
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ADAPT MAX 10070
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

7,500 kg

Certification Date
09.04.2025
Testing basis
HP KEYMARK certification scheme rules V14
Testing laboratory
TÜV Rheinland Energy GmbH, DE
Generate PDF Export model CSV
  • Number of models 1

Models

ADAPT MAX 10070 HT / HK 3F
Configure model
Model name
ADAPT MAX 10070 HT / HK 3F
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

53.48 kW

52.92 kW

El input

10.03 kW

15.25 kW

COP

5.33

3.47

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

22.09 kW

13.03 kW

Cooling capacity

60.54

60.20

EER

2.74

4.62

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

60.50 kW

60.00 kW

SEER

5.50

8.18

Pdc Tj = 35°C

60.54 kW

60.20 kW

EER Tj = 35°C

2.74

4.62

Cdc Tj = 35 °C

0.999

0.998

Pdc Tj = 30°C

44.68 kW

44.27 kW

EER Tj = 30°C

4.22

6.47

Cdc Tj = 30 °C

0.998

0.996

Pdc Tj = 25°C

28.62 kW

28.77 kW

EER Tj = 25°C

6.09

9.11

Cdc Tj = 25 °C

0.995

0.992

Pdc Tj = 20°C

19.03 kW

21.93 kW

EER Tj = 20°C

8.54

11.26

Cdc Tj = 20 °C

0.988

0.987

Poff

26 W

26 W

PTO

26 W

26 W

PSB

26 W

26 W

PCK

26 W

26 W

Annual energy consumption Qce

6708 kWh

4502 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

302 %

216 %

Prated

64.40 kW

64.00 kW

SCOP

7.65

5.48

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

64.38 kW

63.99 kW

COP Tj = +2°C

3.43

2.48

Cdh Tj = +2 °C

0.999

0.999

Pdh Tj = +7°C

41.48 kW

41.13 kW

COP Tj = +7°C

6.23

4.45

Cdh Tj = +7 °C

0.996

0.997

Pdh Tj = 12°C

20.79 kW

19.82 kW

COP Tj = 12°C

10.54

7.56

Cdh Tj = +12 °C

0.987

0.990

Pdh Tj = Tbiv

69.79 kW

67.65 kW

COP Tj = Tbiv

3.43

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

69.79 kW

67.65 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.43

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.999

0.999

WTOL

75 °C

75 °C

Poff

26 W

26 W

PTO

26 W

26 W

PSB

26 W

26 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

11359 kWh

15635 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

150 %

Prated

62.40 kW

62.00 kW

SCOP

4.90

3.81

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

37.85 kW

37.52 kW

COP Tj = -7°C

4.00

3.07

Cdh Tj = -7 °C

0.997

0.998

Pdh Tj = +2°C

22.76 kW

22.82 kW

COP Tj = +2°C

6.14

4.77

Cdh Tj = +2 °C

0.993

0.995

Pdh Tj = +7°C

18.90 kW

18.64 kW

COP Tj = +7°C

8.57

6.57

Cdh Tj = +7 °C

0.988

0.991

Pdh Tj = 12°C

20.73 kW

20.24 kW

COP Tj = 12°C

10.06

8.55

Cdh Tj = +12 °C

0.987

0.989

Pdh Tj = Tbiv

50.90 kW

51.95 kW

COP Tj = Tbiv

2.70

2.05

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

40.66 kW

42.43 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.26

1.66

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.999

0.999

WTOL

75 °C

75 °C

Poff

26 W

26 W

PTO

26 W

26 W

PSB

26 W

26 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

21.70 kW

19.60 kW

Annual energy consumption Qhe

31386 kWh

40095 kWh

Pdh Tj = -15°C (if TOL<-20°C)

50.90

51.95

COP Tj = -15°C (if TOL<-20°C)

2.70

2.05

Cdh Tj = -15 °C

0.999

0.999

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

52 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

229 %

171 %

Prated

53.00 kW

53.00 kW

SCOP

5.81

4.35

Tbiv

-10 °C

-10 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

46.79 kW

46.99 kW

COP Tj = -7°C

3.38

2.48

Cdh Tj = -7 °C

0.998

0.999

Pdh Tj = +2°C

28.82 kW

28.81 kW

COP Tj = +2°C

5.49

4.23

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

19.05 kW

18.63 kW

COP Tj = +7°C

8.36

5.91

Cdh Tj = +7 °C

0.989

0.992

Pdh Tj = 12°C

20.95 kW

20.17 kW

COP Tj = 12°C

10.28

7.92

Cdh Tj = +12 °C

0.987

0.990

Pdh Tj = Tbiv

53.05 kW

53.40 kW

COP Tj = Tbiv

2.87

2.10

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

53.05 kW

53.40 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.87

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.999

0.999

WTOL

75 °C

75 °C

Poff

26 W

26 W

PTO

26 W

26 W

PSB

26 W

26 W

PCK

26 W

26 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

18854 kWh

25178 kWh