Certificate holders

Subtype

iTec XTR M 230-1

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
011-1W1003
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
iTec XTR M 230-1
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,870 kg

Certification Date
25.03.2025
Testing basis
HP KEYMARK certification scheme rules rev. 14
Generate PDF Export model CSV
  • Number of models 1

Models

iTec XTR M 230-1
Configure model
Model name
iTec XTR M 230-1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.00 kW

8.00 kW

El input

1.63 kW

2.67 kW

COP

4.91

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

139 %

Prated

8.00 kW

8.00 kW

SCOP

4.85

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.08 kW

7.08 kW

COP Tj = -7°C

2.70

2.02

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.31 kW

4.31 kW

COP Tj = +2°C

4.70

3.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.77 kW

2.77 kW

COP Tj = +7°C

7.00

5.05

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.40 kW

2.40 kW

COP Tj = 12°C

9.00

6.00

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.08 kW

7.08 kW

COP Tj = Tbiv

2.70

2.02

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

7.30 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.40

1.90

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.60 kW

0.70 kW

Annual energy consumption Qhe

3398 kWh

4646 kWh