Certificate holders

Subtype

iTec XTR L & XL 230-1

Certificate Holder
Thermia
Snickaregatan 1
Arvika
Sweden
Registration number
011-1W1002
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
iTec XTR L & XL 230-1
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,250 kg

Certification Date
25.03.2025
Testing basis
HP KEYMARK certification scheme rules rev. 14
Generate PDF Export model CSV
  • Number of models 2

Models

iTec XTR L 230-1
Configure model
Model name
iTec XTR L 230-1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.00 kW

12.00 kW

El input

2.50 kW

4.00 kW

COP

4.80

3.00

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

60 dB(A)

60 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

143 %

Prated

12.00 kW

12.00 kW

SCOP

4.90

3.65

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.62 kW

10.60 kW

COP Tj = -7°C

2.95

2.15

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

6.46 kW

6.46 kW

COP Tj = +2°C

4.83

3.60

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.15 kW

4.20 kW

COP Tj = +7°C

6.50

4.88

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.15 kW

4.20 kW

COP Tj = 12°C

8.00

5.95

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

10.60 kW

10.60 kW

COP Tj = Tbiv

2.95

2.15

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

11.62 kW

11.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.40 kW

0.50 kW

Annual energy consumption Qhe

5051 kWh

6784 kWh

iTec XTR XL 230-1
Configure model
Model name
iTec XTR XL 230-1
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.00 kW

16.00 kW

El input

3.55 kW

5.52 kW

COP

4.51

2.90

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

65 dB(A)

65 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

185 %

139 %

Prated

15.50 kW

14.50 kW

SCOP

4.70

3.55

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.71 kW

12.80 kW

COP Tj = -7°C

2.50

2.00

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

8.35 kW

7.81 kW

COP Tj = +2°C

4.52

3.41

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.37 kW

5.00 kW

COP Tj = +7°C

7.10

5.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.20 kW

4.20 kW

COP Tj = 12°C

9.00

6.58

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.71 kW

12.80 kW

COP Tj = Tbiv

2.50

2.00

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

13.50 kW

12.50 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.31

1.85

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

22 W

22 W

PTO

22 W

22 W

PSB

22 W

22 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.00 kW

2.00 kW

Annual energy consumption Qhe

6793 kWh

8403 kWh