1,050 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
4.84 kW
4.10 kW
El input
1.20 kW
1.58 kW
COP
4.03
2.60
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
0 dB(A)
0 dB(A)
Sound power level outdoor
60 dB(A)
60 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
167 %
119 %
Prated
4.40 kW
4.40 kW
SCOP
4.25
3.06
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.89 kW
3.89 kW
COP Tj = -7°C
2.64
1.82
Pdh Tj = +2°C
2.37 kW
2.37 kW
COP Tj = +2°C
4.35
3.11
Pdh Tj = +7°C
2.16 kW
1.92 kW
COP Tj = +7°C
5.93
4.15
Pdh Tj = 12°C
1.15 kW
0.96 kW
COP Tj = 12°C
7.55
5.03
Pdh Tj = Tbiv
3.89 kW
3.89 kW
COP Tj = Tbiv
2.64
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.72 kW
3.41 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.57
1.52
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.84
0.89
WTOL
55 °C
55 °C
Poff
5 W
5 W
PTO
60 W
50 W
PSB
5 W
5 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.70 kW
1.00 kW
Annual energy consumption Qhe
2137 kWh
2973 kWh