0,920 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
9.00 kW
9.00 kW
El input
1.86 kW
2.86 kW
COP
4.85
3.15
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
304 %
208 %
Prated
8.60 kW
8.80 kW
SCOP
7.69
5.26
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
8.64 kW
8.80 kW
COP Tj = +2°C
3.59
2.47
Cdh Tj = +2 °C
0.995
0.996
Pdh Tj = +7°C
5.72 kW
5.83 kW
COP Tj = +7°C
6.31
4.28
Cdh Tj = +7 °C
0.986
0.990
Pdh Tj = 12°C
2.66 kW
2.63 kW
COP Tj = 12°C
10.56
7.26
Cdh Tj = +12 °C
0.948
0.964
Pdh Tj = Tbiv
8.64 kW
8.80 kW
COP Tj = Tbiv
3.59
2.47
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
8.64 kW
8.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.59
2.47
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.996
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1495 kWh
2234 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
179 %
138 %
Prated
8.30 kW
8.60 kW
SCOP
4.55
3.51
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
5.07 kW
5.37 kW
COP Tj = -7°C
3.65
2.84
Cdh Tj = -7 °C
0.991
0.993
Pdh Tj = +2°C
3.02 kW
3.17 kW
COP Tj = +2°C
5.68
4.39
Cdh Tj = +2 °C
0.976
0.982
Pdh Tj = +7°C
2.11 kW
2.11 kW
COP Tj = +7°C
7.84
6.05
Cdh Tj = +7 °C
0.952
0.963
Pdh Tj = 12°C
2.08 kW
1.89 kW
COP Tj = 12°C
9.59
7.14
Cdh Tj = +12 °C
0.940
0.951
Pdh Tj = Tbiv
6.83 kW
7.16 kW
COP Tj = Tbiv
2.63
1.93
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.58 kW
5.52 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.04
1.46
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.70 kW
3.10 kW
Annual energy consumption Qhe
4495 kWh
6034 kWh
Pdh Tj = -15°C (if TOL<-20°C)
6.83
7.16
COP Tj = -15°C (if TOL<-20°C)
2.63
1.93
Cdh Tj = -15 °C
0.995
0.996
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
55 dB(A)
55 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
150 %
Prated
9.00 kW
9.00 kW
SCOP
5.15
3.82
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.03 kW
8.03 kW
COP Tj = -7°C
2.97
2.19
Cdh Tj = -7 °C
0.995
0.996
Pdh Tj = +2°C
4.84 kW
4.82 kW
COP Tj = +2°C
4.85
3.73
Cdh Tj = +2 °C
0.987
0.990
Pdh Tj = +7°C
3.09 kW
2.96 kW
COP Tj = +7°C
7.80
5.57
Cdh Tj = +7 °C
0.967
0.976
Pdh Tj = 12°C
1.75 kW
2.10 kW
COP Tj = 12°C
8.84
7.99
Cdh Tj = +12 °C
0.934
0.951
Pdh Tj = Tbiv
8.03 kW
8.03 kW
COP Tj = Tbiv
2.97
2.19
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.40 kW
7.74 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.70
2.05
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.995
0.997
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.30 kW
Annual energy consumption Qhe
3612 kWh
4749 kWh