Certificate holders

Subtype

SHERPA MONOBLOC S4 P 9

Certificate Holder
Olimpia Splendid S.p.A.
Via Industriale, 1/3
25060 Cellatica (BS)
Italy
Registration number
011-1W1026
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
SHERPA MONOBLOC S4 P 9
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,920 kg

Certification Date
27.03.2025
Testing basis
HP KEYMARK certification scheme rules V14
Generate PDF Export model CSV
  • Number of models 1

Models

SHERPA MONOBLOC S4 P 9
Configure model
Model name
SHERPA MONOBLOC S4 P 9
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.00 kW

9.00 kW

El input

1.86 kW

2.86 kW

COP

4.85

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

304 %

208 %

Prated

8.60 kW

8.80 kW

SCOP

7.69

5.26

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.64 kW

8.80 kW

COP Tj = +2°C

3.59

2.47

Cdh Tj = +2 °C

0.995

0.996

Pdh Tj = +7°C

5.72 kW

5.83 kW

COP Tj = +7°C

6.31

4.28

Cdh Tj = +7 °C

0.986

0.990

Pdh Tj = 12°C

2.66 kW

2.63 kW

COP Tj = 12°C

10.56

7.26

Cdh Tj = +12 °C

0.948

0.964

Pdh Tj = Tbiv

8.64 kW

8.80 kW

COP Tj = Tbiv

3.59

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.64 kW

8.80 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.59

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.996

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

13 W

13 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1495 kWh

2234 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

179 %

138 %

Prated

8.30 kW

8.60 kW

SCOP

4.55

3.51

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

5.07 kW

5.37 kW

COP Tj = -7°C

3.65

2.84

Cdh Tj = -7 °C

0.991

0.993

Pdh Tj = +2°C

3.02 kW

3.17 kW

COP Tj = +2°C

5.68

4.39

Cdh Tj = +2 °C

0.976

0.982

Pdh Tj = +7°C

2.11 kW

2.11 kW

COP Tj = +7°C

7.84

6.05

Cdh Tj = +7 °C

0.952

0.963

Pdh Tj = 12°C

2.08 kW

1.89 kW

COP Tj = 12°C

9.59

7.14

Cdh Tj = +12 °C

0.940

0.951

Pdh Tj = Tbiv

6.83 kW

7.16 kW

COP Tj = Tbiv

2.63

1.93

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.58 kW

5.52 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.04

1.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

13 W

13 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.70 kW

3.10 kW

Annual energy consumption Qhe

4495 kWh

6034 kWh

Pdh Tj = -15°C (if TOL<-20°C)

6.83

7.16

COP Tj = -15°C (if TOL<-20°C)

2.63

1.93

Cdh Tj = -15 °C

0.995

0.996

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

203 %

150 %

Prated

9.00 kW

9.00 kW

SCOP

5.15

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.03 kW

8.03 kW

COP Tj = -7°C

2.97

2.19

Cdh Tj = -7 °C

0.995

0.996

Pdh Tj = +2°C

4.84 kW

4.82 kW

COP Tj = +2°C

4.85

3.73

Cdh Tj = +2 °C

0.987

0.990

Pdh Tj = +7°C

3.09 kW

2.96 kW

COP Tj = +7°C

7.80

5.57

Cdh Tj = +7 °C

0.967

0.976

Pdh Tj = 12°C

1.75 kW

2.10 kW

COP Tj = 12°C

8.84

7.99

Cdh Tj = +12 °C

0.934

0.951

Pdh Tj = Tbiv

8.03 kW

8.03 kW

COP Tj = Tbiv

2.97

2.19

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.40 kW

7.74 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.70

2.05

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.995

0.997

WTOL

75 °C

75 °C

Poff

12 W

12 W

PTO

13 W

13 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.30 kW

Annual energy consumption Qhe

3612 kWh

4749 kWh