0,700 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.45 kW
6.30 kW
El input
1.32 kW
1.97 kW
COP
4.90
3.20
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
288 %
202 %
Prated
6.00 kW
6.00 kW
SCOP
7.27
5.14
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
6.08 kW
6.06 kW
COP Tj = +2°C
3.98
2.64
Cdh Tj = +2 °C
0.991
0.994
Pdh Tj = +7°C
3.92 kW
3.91 kW
COP Tj = +7°C
6.17
4.21
Cdh Tj = +7 °C
0.978
0.985
Pdh Tj = 12°C
1.78 kW
1.81 kW
COP Tj = 12°C
9.46
6.95
Cdh Tj = +12 °C
0.926
0.946
Pdh Tj = Tbiv
6.08 kW
6.06 kW
COP Tj = Tbiv
3.98
2.64
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
6.08 kW
6.06 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.98
2.64
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.991
0.994
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
14 W
14 W
PSB
13 W
13 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1102 kWh
1561 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
171 %
135 %
Prated
6.30 kW
6.10 kW
SCOP
4.35
3.44
Tbiv
-15 °C
-15 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
3.82 kW
3.65 kW
COP Tj = -7°C
3.73
2.75
Cdh Tj = -7 °C
0.986
0.989
Pdh Tj = +2°C
2.42 kW
2.28 kW
COP Tj = +2°C
5.05
4.09
Cdh Tj = +2 °C
0.971
0.975
Pdh Tj = +7°C
1.92 kW
1.84 kW
COP Tj = +7°C
7.72
6.16
Cdh Tj = +7 °C
0.944
0.953
Pdh Tj = 12°C
1.71 kW
1.64 kW
COP Tj = 12°C
9.87
8.45
Cdh Tj = +12 °C
0.919
0.928
Pdh Tj = Tbiv
5.18 kW
5.13 kW
COP Tj = Tbiv
2.56
2.13
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.98 kW
3.91 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.21
1.60
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
14 W
14 W
PSB
13 W
13 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.30 kW
2.20 kW
Annual energy consumption Qhe
3573 kWh
4371 kWh
Pdh Tj = -15°C (if TOL<-20°C)
5.18
5.13
COP Tj = -15°C (if TOL<-20°C)
2.56
2.13
Cdh Tj = -15 °C
0.993
0.994
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
52 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
149 %
Prated
6.10 kW
5.60 kW
SCOP
5.17
3.79
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.51 kW
5.06 kW
COP Tj = -7°C
3.17
2.40
Cdh Tj = -7 °C
0.992
0.993
Pdh Tj = +2°C
3.28 kW
3.03 kW
COP Tj = +2°C
4.91
3.58
Cdh Tj = +2 °C
0.979
0.983
Pdh Tj = +7°C
2.12 kW
1.97 kW
COP Tj = +7°C
7.15
5.06
Cdh Tj = +7 °C
0.953
0.964
Pdh Tj = 12°C
1.70 kW
1.61 kW
COP Tj = 12°C
9.56
7.15
Cdh Tj = +12 °C
0.921
0.938
Pdh Tj = Tbiv
5.51 kW
5.06 kW
COP Tj = Tbiv
3.17
2.40
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.18 kW
4.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.99
2.18
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.992
0.994
WTOL
75 °C
75 °C
Poff
13 W
13 W
PTO
14 W
14 W
PSB
13 W
13 W
PCK
1 W
1 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.90 kW
0.80 kW
Annual energy consumption Qhe
2440 kWh
3056 kWh