Certificate holders

Subtype

Auriga-P 8

Certificate Holder
BAXI S.p.A.
Via Trozzetti, 20
Bassano del Grappa (VI)
Italy
Registration number
ICIM-PDC-000324
Certification Body
ICIM S.p.A.
Subtype title
Auriga-P 8
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,100 kg

Certification Date
04.04.2025
Testing basis
V12
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Auriga-P 8M
Configure model
Model name
Auriga-P 8M
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.50 kW

8.00 kW

El input

1.71 kW

2.52 kW

COP

4.98

3.18

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 14825

Low temperature

Medium temperature

ηs

205.1 %

152.7 %

Prated

8.00 kW

7.80 kW

SCOP

5.20

3.89

Tbiv

-7.00 °C

-7.00 °C

TOL

-10.00 °C

-10.00 °C

Pdh Tj = -7°C

7.39 kW

6.95 kW

COP Tj = -7°C

3.11

2.36

Cdh Tj = -7 °C

1.00

1.00

Pdh Tj = +2°C

4.27 kW

4.09 kW

COP Tj = +2°C

5.12

3.83

Cdh Tj = +2 °C

1.00

1.00

Pdh Tj = +7°C

3.66 kW

3.47 kW

COP Tj = +7°C

6.85

5.05

Cdh Tj = +7 °C

0.98

0.99

Pdh Tj = 12°C

4.33 kW

4.03 kW

COP Tj = 12°C

8.90

6.41

Cdh Tj = +12 °C

0.98

0.99

Pdh Tj = Tbiv

7.39 kW

6.95 kW

COP Tj = Tbiv

3.11

2.36

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.00 kW

7.71 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.59

2.02

WTOL

75.00 °C

75.00 °C

Poff

8.90 W

8.90 W

PTO

9.00 W

9.00 W

PSB

8.90 W

8.90 W

PCK

0.00 W

0.00 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.09 kW

Annual energy consumption Qhe

3176 kWh

4140 kWh