1,350 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.34 kW
12.36 kW
El input
2.48 kW
3.89 kW
COP
4.98
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.60 kW
2.65 kW
Cooling capacity
11.55
12.39
EER
3.21
4.67
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.55 kW
12.39 kW
SEER
5.44
7.08
Pdc Tj = 35°C
11.55 kW
12.39 kW
EER Tj = 35°C
3.21
4.67
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
8.66 kW
9.53 kW
EER Tj = 30°C
4.79
6.92
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.80 kW
6.06 kW
EER Tj = 25°C
6.53
7.75
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
4.76 kW
6.03 kW
EER Tj = 20°C
6.41
8.58
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
0 W
0 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1273 kWh
1050 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
189 %
Prated
11.83 kW
12.22 kW
SCOP
6.44
4.79
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.83 kW
12.22 kW
COP Tj = +2°C
3.51
2.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.93 kW
8.17 kW
COP Tj = +7°C
6.17
4.23
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.92 kW
COP Tj = 12°C
7.90
6.34
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.83 kW
12.20 kW
COP Tj = Tbiv
3.51
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.83 kW
12.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2456 kWh
3410 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
145 %
Prated
12.36 kW
12.00 kW
SCOP
4.74
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.93 kW
10.62 kW
COP Tj = -7°C
2.93
2.29
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.95 kW
6.85 kW
COP Tj = +2°C
4.60
3.67
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.03 kW
5.51 kW
COP Tj = +7°C
6.71
5.00
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.05 kW
5.83 kW
COP Tj = 12°C
8.08
6.68
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.93 kW
10.62 kW
COP Tj = Tbiv
2.93
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.35 kW
9.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.01 kW
2.21 kW
Annual energy consumption Qhe
5387 kWh
6695 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.24 kW
14.33 kW
El input
3.06 kW
4.64 kW
COP
4.65
3.09
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.44 kW
3.21 kW
Cooling capacity
13.26
14.16
EER
2.99
4.42
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
13.26 kW
14.16 kW
SEER
5.30
7.25
Pdc Tj = 35°C
13.26 kW
14.16 kW
EER Tj = 35°C
2.99
4.42
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
9.96 kW
10.79 kW
EER Tj = 30°C
4.51
6.58
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.42 kW
6.85 kW
EER Tj = 25°C
6.33
8.46
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
4.82 kW
6.06 kW
EER Tj = 20°C
6.50
8.60
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
0 W
0 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1501 kWh
1172 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
251 %
189 %
Prated
12.92 kW
13.02 kW
SCOP
6.34
4.80
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.92 kW
13.02 kW
COP Tj = +2°C
3.30
2.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.46 kW
8.50 kW
COP Tj = +7°C
5.88
4.20
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.94 kW
COP Tj = 12°C
7.98
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.92 kW
13.02 kW
COP Tj = Tbiv
3.30
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.92 kW
13.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.41
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2722 kWh
3622 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
146 %
Prated
13.76 kW
13.11 kW
SCOP
4.76
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.17 kW
11.60 kW
COP Tj = -7°C
2.86
2.25
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.58 kW
7.46 kW
COP Tj = +2°C
4.54
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.12 kW
5.56 kW
COP Tj = +7°C
7.00
5.11
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.03 kW
5.87 kW
COP Tj = 12°C
8.09
6.76
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.17 kW
11.60 kW
COP Tj = Tbiv
2.86
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.84 kW
10.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.91 kW
2.48 kW
Annual energy consumption Qhe
5972 kWh
7264 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.30 kW
15.53 kW
El input
3.37 kW
5.15 kW
COP
4.54
3.02
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.05 kW
3.89 kW
Cooling capacity
14.48
16.29
EER
2.87
4.19
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.50 kW
16.29 kW
SEER
5.30
6.96
Pdc Tj = 35°C
14.50 kW
16.29 kW
EER Tj = 35°C
2.87
4.19
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
10.96 kW
12.32 kW
EER Tj = 30°C
4.48
6.16
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
7.05 kW
7.82 kW
EER Tj = 25°C
6.16
7.91
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
5.21 kW
6.10 kW
EER Tj = 20°C
6.95
8.68
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
0 W
0 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1643 kWh
1403 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
191 %
Prated
14.04 kW
13.55 kW
SCOP
6.37
4.85
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14.04 kW
13.55 kW
COP Tj = +2°C
3.17
2.39
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.15 kW
8.86 kW
COP Tj = +7°C
5.86
4.23
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.05 kW
5.95 kW
COP Tj = 12°C
8.03
6.46
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.04 kW
13.55 kW
COP Tj = Tbiv
3.17
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.04 kW
13.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.17
2.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2945 kWh
3733 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
146 %
Prated
15.00 kW
14.55 kW
SCOP
4.75
3.72
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.26 kW
12.87 kW
COP Tj = -7°C
2.75
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.23 kW
8.33 kW
COP Tj = +2°C
4.51
3.63
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.42 kW
5.35 kW
COP Tj = +7°C
7.26
5.30
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.89 kW
COP Tj = 12°C
8.13
6.81
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.26 kW
12.87 kW
COP Tj = Tbiv
2.75
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.55 kW
11.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.44 kW
3.15 kW
Annual energy consumption Qhe
6518 kWh
8071 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.34 kW
12.36 kW
El input
2.48 kW
3.89 kW
COP
4.98
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
3.60 kW
2.65 kW
Cooling capacity
11.55
12.39
EER
3.21
4.67
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
11.55 kW
12.39 kW
SEER
5.44
7.08
Pdc Tj = 35°C
11.55 kW
12.39 kW
EER Tj = 35°C
3.21
4.67
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
8.66 kW
9.53 kW
EER Tj = 30°C
4.79
6.92
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
5.80 kW
6.06 kW
EER Tj = 25°C
6.53
7.75
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
4.76 kW
6.03 kW
EER Tj = 20°C
6.41
8.58
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
0 W
0 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1273 kWh
1050 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
254 %
189 %
Prated
11.83 kW
12.22 kW
SCOP
6.44
4.79
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
11.83 kW
12.22 kW
COP Tj = +2°C
3.51
2.50
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
7.93 kW
8.17 kW
COP Tj = +7°C
6.17
4.23
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.92 kW
COP Tj = 12°C
7.90
6.34
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
11.83 kW
12.20 kW
COP Tj = Tbiv
3.51
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.83 kW
12.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.51
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2456 kWh
3410 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
63 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
145 %
Prated
12.36 kW
12.00 kW
SCOP
4.74
3.70
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.93 kW
10.62 kW
COP Tj = -7°C
2.93
2.29
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
6.95 kW
6.85 kW
COP Tj = +2°C
4.60
3.67
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.03 kW
5.51 kW
COP Tj = +7°C
6.71
5.00
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.05 kW
5.83 kW
COP Tj = 12°C
8.08
6.68
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.93 kW
10.62 kW
COP Tj = Tbiv
2.93
2.29
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.35 kW
9.80 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.01 kW
2.21 kW
Annual energy consumption Qhe
5387 kWh
6695 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
14.24 kW
14.33 kW
El input
3.06 kW
4.64 kW
COP
4.65
3.09
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
4.44 kW
3.21 kW
Cooling capacity
13.26
14.16
EER
2.99
4.42
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
13.26 kW
14.16 kW
SEER
5.30
7.25
Pdc Tj = 35°C
13.26 kW
14.16 kW
EER Tj = 35°C
2.99
4.42
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
9.96 kW
10.79 kW
EER Tj = 30°C
4.51
6.58
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
6.42 kW
6.85 kW
EER Tj = 25°C
6.33
8.46
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
4.82 kW
6.06 kW
EER Tj = 20°C
6.50
8.60
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
0 W
0 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1501 kWh
1172 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
251 %
189 %
Prated
12.92 kW
13.02 kW
SCOP
6.34
4.80
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
12.92 kW
13.02 kW
COP Tj = +2°C
3.30
2.41
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
8.46 kW
8.50 kW
COP Tj = +7°C
5.88
4.20
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.94 kW
COP Tj = 12°C
7.98
6.40
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.92 kW
13.02 kW
COP Tj = Tbiv
3.30
2.41
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.92 kW
13.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.30
2.41
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2722 kWh
3622 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
64 dB(A)
64 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
146 %
Prated
13.76 kW
13.11 kW
SCOP
4.76
3.73
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
12.17 kW
11.60 kW
COP Tj = -7°C
2.86
2.25
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.58 kW
7.46 kW
COP Tj = +2°C
4.54
3.66
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.12 kW
5.56 kW
COP Tj = +7°C
7.00
5.11
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.03 kW
5.87 kW
COP Tj = 12°C
8.09
6.76
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
12.17 kW
11.60 kW
COP Tj = Tbiv
2.86
2.25
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
11.84 kW
10.63 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.62
2.04
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.91 kW
2.48 kW
Annual energy consumption Qhe
5972 kWh
7264 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.30 kW
15.53 kW
El input
3.37 kW
5.15 kW
COP
4.54
3.02
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
5.05 kW
3.89 kW
Cooling capacity
14.48
16.29
EER
2.87
4.19
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
14.50 kW
16.29 kW
SEER
5.30
6.96
Pdc Tj = 35°C
14.50 kW
16.29 kW
EER Tj = 35°C
2.87
4.19
Cdc Tj = 35 °C
0.900
0.900
Pdc Tj = 30°C
10.96 kW
12.32 kW
EER Tj = 30°C
4.48
6.16
Cdc Tj = 30 °C
0.900
0.900
Pdc Tj = 25°C
7.05 kW
7.82 kW
EER Tj = 25°C
6.16
7.91
Cdc Tj = 25 °C
0.900
0.900
Pdc Tj = 20°C
5.21 kW
6.10 kW
EER Tj = 20°C
6.95
8.68
Cdc Tj = 20 °C
0.900
0.900
Poff
9 W
9 W
PTO
0 W
0 W
PSB
9 W
9 W
PCK
0 W
0 W
Annual energy consumption Qce
1643 kWh
1403 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
191 %
Prated
14.04 kW
13.55 kW
SCOP
6.37
4.85
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
14.04 kW
13.55 kW
COP Tj = +2°C
3.17
2.39
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.15 kW
8.86 kW
COP Tj = +7°C
5.86
4.23
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.05 kW
5.95 kW
COP Tj = 12°C
8.03
6.46
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
14.04 kW
13.55 kW
COP Tj = Tbiv
3.17
2.39
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
14.04 kW
13.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.17
2.39
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
2945 kWh
3733 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
65 dB(A)
65 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
146 %
Prated
15.00 kW
14.55 kW
SCOP
4.75
3.72
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.26 kW
12.87 kW
COP Tj = -7°C
2.75
2.17
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
8.23 kW
8.33 kW
COP Tj = +2°C
4.51
3.63
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
5.42 kW
5.35 kW
COP Tj = +7°C
7.26
5.30
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
6.04 kW
5.89 kW
COP Tj = 12°C
8.13
6.81
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
13.26 kW
12.87 kW
COP Tj = Tbiv
2.75
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.55 kW
11.40 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.56
2.01
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
9 W
9 W
PTO
9 W
9 W
PSB
9 W
9 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.44 kW
3.15 kW
Annual energy consumption Qhe
6518 kWh
8071 kWh