Certificate holders

Subtype

ASThermal i 8-10 series

Certificate Holder
Guangdong Answer Technology Co., Ltd.​
1st & 2nd Floor, Building B, No.7, Xinde Road,Ronggui, Shunde, Foshan,
528303 Guangdong
China
Registration number
011-1W1021
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
ASThermal i 8-10 series
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,070 kg

Certification Date
18.03.2025
Testing basis
HP KEYMARK certification scheme rules rev. 14
Generate PDF Export model CSV
  • Number of models 4

Models

AMH-8R2
Configure model
Model name
AMH-8R2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.30 kW

7.87 kW

El input

1.64 kW

2.38 kW

COP

5.09

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.18 kW

1.63 kW

Cooling capacity

7.52

8.40

EER

3.45

5.17

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.52 kW

8.40 kW

SEER

5.49

7.44

Pdc Tj = 35°C

7.51 kW

8.40 kW

EER Tj = 35°C

3.45

5.17

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

5.72 kW

6.43 kW

EER Tj = 30°C

4.90

6.79

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.85 kW

4.83 kW

EER Tj = 25°C

6.35

8.71

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.78 kW

4.58 kW

EER Tj = 20°C

6.94

9.18

Cdc Tj = 20 °C

0.900

0.900

Poff

8 W

8 W

PTO

0 W

0 W

PSB

8 W

8 W

PCK

0 W

0 W

Annual energy consumption Qce

822 kWh

678 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

264 %

187 %

Prated

8.25 kW

8.24 kW

SCOP

6.68

4.75

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.25 kW

8.23 kW

COP Tj = +2°C

3.65

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.56 kW

5.60 kW

COP Tj = +7°C

6.16

4.19

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.51 kW

4.32 kW

COP Tj = 12°C

8.62

6.38

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.25 kW

8.23 kW

COP Tj = Tbiv

3.65

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.25 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.65

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1649 kWh

2317 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

153 %

Prated

8.15 kW

7.35 kW

SCOP

5.01

3.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.21 kW

6.50 kW

COP Tj = -7°C

3.00

2.32

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.62 kW

4.16 kW

COP Tj = +2°C

4.98

3.98

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.91 kW

3.73 kW

COP Tj = +7°C

6.99

5.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.55 kW

4.32 kW

COP Tj = 12°C

8.99

6.74

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.21 kW

6.50 kW

COP Tj = Tbiv

3.00

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.83 kW

6.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.39 kW

Annual energy consumption Qhe

3357 kWh

3899 kWh

AMH-10R2
Configure model
Model name
AMH-10R2
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.99 kW

9.53 kW

El input

2.11 kW

3.01 kW

COP

4.73

3.16

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.70 kW

2.11 kW

Cooling capacity

8.58

10.02

EER

3.18

4.75

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.58 kW

10.02 kW

SEER

5.45

7.59

Pdc Tj = 35°C

8.58 kW

10.02 kW

EER Tj = 35°C

3.18

4.75

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

6.63 kW

7.60 kW

EER Tj = 30°C

4.63

6.93

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.16 kW

4.89 kW

EER Tj = 25°C

6.33

8.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.85 kW

4.64 kW

EER Tj = 20°C

7.29

9.24

Cdc Tj = 20 °C

0.900

0.900

Poff

8 W

8 W

PTO

0 W

0 W

PSB

8 W

8 W

PCK

0 W

0 W

Annual energy consumption Qce

944 kWh

792 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

189 %

Prated

8.60 kW

8.87 kW

SCOP

6.71

4.79

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.60 kW

8.87 kW

COP Tj = +2°C

3.54

2.46

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.71 kW

5.78 kW

COP Tj = +7°C

6.16

4.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.52 kW

4.35 kW

COP Tj = 12°C

8.68

6.45

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.60 kW

8.87 kW

COP Tj = Tbiv

3.54

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.60 kW

8.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1712 kWh

2474 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

153 %

Prated

9.26 kW

8.40 kW

SCOP

4.95

3.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.19 kW

7.43 kW

COP Tj = -7°C

2.79

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.01 kW

4.67 kW

COP Tj = +2°C

4.90

3.93

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.92 kW

3.75 kW

COP Tj = +7°C

7.08

5.32

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.55 kW

4.34 kW

COP Tj = 12°C

9.01

6.82

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.19 kW

7.43 kW

COP Tj = Tbiv

2.79

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.59 kW

7.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.67 kW

0.64 kW

Annual energy consumption Qhe

3865 kWh

4457 kWh

AMH-8R2B3
Configure model
Model name
AMH-8R2B3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

8.30 kW

7.87 kW

El input

1.64 kW

2.38 kW

COP

5.09

3.31

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.18 kW

1.63 kW

Cooling capacity

7.52

8.40

EER

3.45

5.17

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

7.52 kW

8.40 kW

SEER

5.49

7.44

Pdc Tj = 35°C

7.51 kW

8.40 kW

EER Tj = 35°C

3.45

5.17

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

5.72 kW

6.43 kW

EER Tj = 30°C

4.90

6.79

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

3.85 kW

4.83 kW

EER Tj = 25°C

6.35

8.71

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.78 kW

4.58 kW

EER Tj = 20°C

6.94

9.18

Cdc Tj = 20 °C

0.900

0.900

Poff

8 W

8 W

PTO

0 W

0 W

PSB

8 W

8 W

PCK

0 W

0 W

Annual energy consumption Qce

822 kWh

678 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

264 %

187 %

Prated

8.25 kW

8.24 kW

SCOP

6.68

4.75

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.25 kW

8.23 kW

COP Tj = +2°C

3.65

2.48

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.56 kW

5.60 kW

COP Tj = +7°C

6.16

4.19

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.51 kW

4.32 kW

COP Tj = 12°C

8.62

6.38

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.25 kW

8.23 kW

COP Tj = Tbiv

3.65

2.48

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.25 kW

8.23 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.65

2.48

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1649 kWh

2317 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

153 %

Prated

8.15 kW

7.35 kW

SCOP

5.01

3.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

7.21 kW

6.50 kW

COP Tj = -7°C

3.00

2.32

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.62 kW

4.16 kW

COP Tj = +2°C

4.98

3.98

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.91 kW

3.73 kW

COP Tj = +7°C

6.99

5.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.55 kW

4.32 kW

COP Tj = 12°C

8.99

6.74

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

7.21 kW

6.50 kW

COP Tj = Tbiv

3.00

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.83 kW

6.96 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

2.02

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.39 kW

Annual energy consumption Qhe

3357 kWh

3899 kWh

AMH-10R2B3
Configure model
Model name
AMH-10R2B3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
+7°C/12°C and +18°C/+23°C
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.99 kW

9.53 kW

El input

2.11 kW

3.01 kW

COP

4.73

3.16

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Cooling

EN 14511-2

+7°C/+12°C

+18°C/+23°C

El input

2.70 kW

2.11 kW

Cooling capacity

8.58

10.02

EER

3.18

4.75

EN 14825

+7°C/+12°C

+18°C/+23°C

Pdesignc

8.58 kW

10.02 kW

SEER

5.45

7.59

Pdc Tj = 35°C

8.58 kW

10.02 kW

EER Tj = 35°C

3.18

4.75

Cdc Tj = 35 °C

0.900

0.900

Pdc Tj = 30°C

6.63 kW

7.60 kW

EER Tj = 30°C

4.63

6.93

Cdc Tj = 30 °C

0.900

0.900

Pdc Tj = 25°C

4.16 kW

4.89 kW

EER Tj = 25°C

6.33

8.78

Cdc Tj = 25 °C

0.900

0.900

Pdc Tj = 20°C

3.85 kW

4.64 kW

EER Tj = 20°C

7.29

9.24

Cdc Tj = 20 °C

0.900

0.900

Poff

8 W

8 W

PTO

0 W

0 W

PSB

8 W

8 W

PCK

0 W

0 W

Annual energy consumption Qce

944 kWh

792 kWh

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

265 %

189 %

Prated

8.60 kW

8.87 kW

SCOP

6.71

4.79

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

8.60 kW

8.87 kW

COP Tj = +2°C

3.54

2.46

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.71 kW

5.78 kW

COP Tj = +7°C

6.16

4.18

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.52 kW

4.35 kW

COP Tj = 12°C

8.68

6.45

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.60 kW

8.87 kW

COP Tj = Tbiv

3.54

2.46

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.60 kW

8.87 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.54

2.46

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1712 kWh

2474 kWh

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

195 %

153 %

Prated

9.26 kW

8.40 kW

SCOP

4.95

3.90

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.19 kW

7.43 kW

COP Tj = -7°C

2.79

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.01 kW

4.67 kW

COP Tj = +2°C

4.90

3.93

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.92 kW

3.75 kW

COP Tj = +7°C

7.08

5.32

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

4.55 kW

4.34 kW

COP Tj = 12°C

9.01

6.82

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.19 kW

7.43 kW

COP Tj = Tbiv

2.79

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

8.59 kW

7.76 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.46

1.96

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

8 W

8 W

PTO

8 W

8 W

PSB

8 W

8 W

PCK

8 W

8 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.67 kW

0.64 kW

Annual energy consumption Qhe

3865 kWh

4457 kWh