1,430 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
12.00 kW
12.00 kW
El input
2.50 kW
3.87 kW
COP
4.80
3.10
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
197 %
150 %
Prated
12.10 kW
12.10 kW
SCOP
4.99
3.82
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.79 kW
10.73 kW
COP Tj = -7°C
2.86
2.31
Cdh Tj = -7 °C
0.997
0.997
Pdh Tj = +2°C
6.48 kW
6.66 kW
COP Tj = +2°C
4.70
3.72
Cdh Tj = +2 °C
0.991
0.993
Pdh Tj = +7°C
4.27 kW
4.23 kW
COP Tj = +7°C
7.40
5.44
Cdh Tj = +7 °C
0.977
0.983
Pdh Tj = 12°C
3.80 kW
3.76 kW
COP Tj = 12°C
9.14
7.28
Cdh Tj = +12 °C
0.969
0.975
Pdh Tj = Tbiv
10.79 kW
10.73 kW
COP Tj = Tbiv
2.86
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.45 kW
10.49 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.78
2.09
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.997
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.60 kW
1.60 kW
Annual energy consumption Qhe
5008 kWh
6396 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
15.00 kW
15.00 kW
El input
3.41 kW
5.26 kW
COP
4.40
2.85
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
58 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
190 %
147 %
Prated
14.70 kW
14.50 kW
SCOP
4.83
3.76
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.24 kW
13.40 kW
COP Tj = -7°C
2.70
2.17
Cdh Tj = -7 °C
0.997
0.998
Pdh Tj = +2°C
8.02 kW
7.70 kW
COP Tj = +2°C
4.49
3.52
Cdh Tj = +2 °C
0.993
0.994
Pdh Tj = +7°C
5.14 kW
5.12 kW
COP Tj = +7°C
7.46
5.44
Cdh Tj = +7 °C
0.981
0.986
Pdh Tj = 12°C
3.80 kW
3.76 kW
COP Tj = 12°C
9.15
7.28
Cdh Tj = +12 °C
0.969
0.975
Pdh Tj = Tbiv
13.24 kW
13.40 kW
COP Tj = Tbiv
2.70
2.17
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.81 kW
12.55 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.61
2.02
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.997
0.998
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
13 W
13 W
PSB
12 W
12 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.90 kW
2.00 kW
Annual energy consumption Qhe
6285 kWh
7977 kWh