Certificate holders

Subtype

NIBE AMS 10-6

Certificate Holder
Nibe AB
Box 14
S-28521 Markaryd
Sweden
Registration number
012-SC0603-18 / Issue 6
Certification Body
RISE CERT
Subtype title
NIBE AMS 10-6
Driving energy
n/a
Heat Pump Type
Outdoor Air/Water
Refrigerant
R410A
Mass of Refrigerant

1,500 kg

Certification Date
20.09.2018
Testing basis
EN 14511:2018, EN 16147:2017, EN 14825:2018, EN 12102:2017
Generate PDF Export model CSV Download certificate
  • Number of models 6

Models

NIBE AMS 10-6 + HBS05-6
Configure model
Model name
NIBE AMS 10-6 + HBS05-6
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

2.42 kW

1.57 kW

El input

0.50 kW

0.76 kW

COP

4.85

2.06

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

NIBE AMS 10-6 + HK200S-6
Configure model
Model name
NIBE AMS 10-6 + HK200S-6
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

2.42 kW

1.57 kW

El input

0.50 kW

0.76 kW

COP

4.85

2.06

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

91 %

COP

2.22

Heating up time

01:40 h:min

Standby power input

45.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

230 l

NIBE AMS10-6 + BA-SVM 10-200/6
Configure model
Model name
NIBE AMS10-6 + BA-SVM 10-200/6
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.80 kW

3.84 kW

El input

0.93 kW

1.37 kW

COP

5.14

2.81

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

91 %

COP

2.22

Heating up time

01:40 h:min

Standby power input

45.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

230 l

NIBE AMS 10-6 + SHB10-6
Configure model
Model name
NIBE AMS 10-6 + SHB10-6
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.80 kW

3.84 kW

El input

0.93 kW

1.37 kW

COP

5.14

2.81

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Cdh Tj = -7 °C

0.98

0.98

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

NIBE AMS 10-6 + SHB 20-6
Configure model
Model name
NIBE AMS 10-6 + SHB 20-6
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.80 kW

3.84 kW

El input

0.93 kW

1.37 kW

COP

5.14

2.81

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Cdh Tj = -7 °C

0.98

0.98

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Cdh Tj = +2 °C

0.98

0.98

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Cdh Tj = +7 °C

0.98

0.98

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Cdh Tj = +12 °C

0.98

0.98

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

NIBE AMS 10-6 + BA-SVM 20-200/6
Configure model
Model name
NIBE AMS 10-6 + BA-SVM 20-200/6
Application
Heating + DHW + low temp
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-4

Operating range outdoor exchanger/indoor exchanger lower limit/lower limit

passed

Operating range outdoor exchanger/indoor exchanger upper limit/upper limit

passed

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

EN 14511-2

Low temperature

Medium temperature

Heat output

4.80 kW

3.84 kW

El input

0.93 kW

1.37 kW

COP

5.14

2.81

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

35 dB(A)

35 dB(A)

Sound power level outdoor

51 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

131 %

Prated

4.80 kW

5.30 kW

SCOP

4.77

3.35

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.30 kW

4.70 kW

COP Tj = -7°C

2.60

1.88

Pdh Tj = +2°C

2.60 kW

2.80 kW

COP Tj = +2°C

4.84

3.26

Pdh Tj = +7°C

1.70 kW

1.80 kW

COP Tj = +7°C

6.91

4.72

Pdh Tj = 12°C

2.70 kW

2.70 kW

COP Tj = 12°C

7.72

6.47

Pdh Tj = Tbiv

4.30 kW

4.70 kW

COP Tj = Tbiv

2.60

1.88

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.20 kW

4.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.24

1.77

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.98

0.99

WTOL

65 °C

65 °C

Poff

7 W

7 W

PTO

12 W

12 W

PSB

12 W

12 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.20 kW

Annual energy consumption Qhe

2089 kWh

3248 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

XL

Efficiency ηDHW

91 %

COP

2.22

Heating up time

01:40 h:min

Standby power input

45.0 W

Reference hot water temperature

51.0 °C

Mixed water at 40°C

230 l