Certificate holders

Subtype

QA-22

Certificate Holder
Qvantum Energi AB
Ji-te gatan 7
265 38 Åstorp
Sweden
Registration number
041-K111-03
Certification Body
BRE
Subtype title
QA-22
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,300 kg

Certification Date
01.02.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

QA-22-3
Configure model
Model name
QA-22-3
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

15.73 kW

17.03 kW

El input

3.94 kW

4.79 kW

COP

3.99

3.56

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

62 dB(A)

61 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

193 %

145 %

Prated

12.55 kW

12.34 kW

SCOP

4.91

3.70

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

11.11 kW

10.92 kW

COP Tj = -7°C

3.23

2.34

Cdh Tj = -7 °C

0.990

0.990

Pdh Tj = +2°C

6.89 kW

6.80 kW

COP Tj = +2°C

4.83

3.58

Cdh Tj = +2 °C

0.990

0.990

Pdh Tj = +7°C

7.30 kW

7.36 kW

COP Tj = +7°C

6.04

4.74

Cdh Tj = +7 °C

0.990

0.990

Pdh Tj = 12°C

7.78 kW

7.39 kW

COP Tj = 12°C

7.46

6.12

Cdh Tj = +12 °C

0.990

0.990

Pdh Tj = Tbiv

11.11 kW

10.92 kW

COP Tj = Tbiv

3.23

2.34

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.61 kW

12.33 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.990

0.990

WTOL

63 °C

63 °C

Poff

11 W

11 W

PTO

11 W

11 W

PSB

11 W

11 W

PCK

17 W

17 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.01 kW

Annual energy consumption Qhe

5281 kWh

6895 kWh