0,630 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.05 kW
5.84 kW
El input
1.14 kW
1.73 kW
COP
5.31
3.37
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
56 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
198 %
149 %
Prated
6.00 kW
5.00 kW
SCOP
5.02
3.85
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.00 kW
4.80 kW
COP Tj = -7°C
3.46
2.52
Cdh Tj = -7 °C
0.980
0.980
Pdh Tj = +2°C
3.00 kW
2.90 kW
COP Tj = +2°C
4.81
3.74
Cdh Tj = +2 °C
0.980
0.980
Pdh Tj = +7°C
2.50 kW
2.50 kW
COP Tj = +7°C
6.40
4.90
Cdh Tj = +7 °C
0.980
0.980
Pdh Tj = 12°C
2.40 kW
2.30 kW
COP Tj = 12°C
8.62
6.73
Cdh Tj = +12 °C
0.980
0.980
Pdh Tj = Tbiv
5.00 kW
4.80 kW
COP Tj = Tbiv
3.46
2.52
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.40 kW
5.20 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.04
2.22
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.980
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
12 W
12 W
PSB
10 W
10 W
PCK
33 W
33 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.60 kW
0.00 kW
Annual energy consumption Qhe
2315 kWh
2902 kWh