Certificate holders

Subtype

Grant Aerona HPR290i90

Certificate Holder
Grant Engineering (Ireland) ULC
Barrack St
R42 D788 Ballinree, Birr
Ireland
Registration number
041-K005-07
Certification Body
BRE Global Limited
Subtype title
Grant Aerona HPR290i90
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,000 kg

Certification Date
14.01.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Grant Aerona HPR290i90
Configure model
Model name
Grant Aerona HPR290i90
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

9.38 kW

9.3 kW

El input

1.9 kW

2.99 kW

COP

4.93

3.11

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

189 %

148 %

Prated

9 kW

8.5 kW

SCOP

4.81

3.77

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.17 kW

7.75 kW

COP Tj = -7°C

2.68

2.33

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

4.89 kW

5.18 kW

COP Tj = +2°C

4.78

3.78

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

3.26 kW

3.25 kW

COP Tj = +7°C

6.84

4.87

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

2.46 kW

2.61 kW

COP Tj = 12°C

7.77

6.55

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

8.38 kW

8.42 kW

COP Tj = Tbiv

3.07

2.12

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

7.52 kW

7.9 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.82

2

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

7 W

7 W

PTO

27 W

27 W

PSB

7 W

7 W

PCK

21 W

21 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.37 kW

0.56 kW

Annual energy consumption Qhe

3864 kWh

4659 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

130.4 %

COP

3.08

Heating up time

02:17 h:min

Standby power input

39 W

Reference hot water temperature

55.2 °C

Mixed water at 40°C

329 l