Certificate holders

Subtype

Grant Aerona HPR290i120

Certificate Holder
Grant Engineering (Ireland) ULC
Barrack St
R42 D788 Ballinree, Birr
Ireland
Registration number
041-K005-08
Certification Body
BRE
Subtype title
Grant Aerona HPR290i120
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,200 kg

Certification Date
14.01.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Grant Aerona HPR290i120
Configure model
Model name
Grant Aerona HPR290i120
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

12.18 kW

12.21 kW

El input

2.53 kW

3.79 kW

COP

4.81

3.22

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

49 dB(A)

52 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

190 %

150 %

Prated

11.2 kW

11.2 kW

SCOP

4.82

3.81

Tbiv

-9 °C

-9 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

10.47 kW

10.43 kW

COP Tj = -7°C

3.12

2.32

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

7.18 kW

6.56 kW

COP Tj = +2°C

4.58

3.76

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

4.56 kW

4.57 kW

COP Tj = +7°C

6.66

5.06

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

3.4 kW

3.2 kW

COP Tj = 12°C

9.01

6.83

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

11.12 kW

10.81 kW

COP Tj = Tbiv

3.01

2.23

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

10.86 kW

10.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.89

2.15

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

7 W

7 W

PTO

27 W

27 W

PSB

7 W

7 W

PCK

21 W

21 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.58 kW

Annual energy consumption Qhe

4803 kWh

6069 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

123.1 %

COP

2.89

Heating up time

01:59 h:min

Standby power input

46 W

Reference hot water temperature

55.4 °C

Mixed water at 40°C

331 l