0,830 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
7.62 kW
7.23 kW
El input
1.54 kW
2.4 kW
COP
4.95
3
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
51 dB(A)
52 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
203 %
145 %
Prated
6.5 kW
6.5 kW
SCOP
5.16
3.7
Tbiv
-9 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
6.33 kW
5.98 kW
COP Tj = -7°C
3.25
2.33
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
4.03 kW
3.99 kW
COP Tj = +2°C
5.22
3.77
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
2.74 kW
2.75 kW
COP Tj = +7°C
6.85
4.74
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
2.24 kW
2.41 kW
COP Tj = 12°C
8.07
6.17
Cdh Tj = +12 °C
0.9
0.9
Pdh Tj = Tbiv
6.18 kW
6.09 kW
COP Tj = Tbiv
2.91
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.99 kW
5.65 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.82
1.97
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
7 W
7 W
PTO
25 W
25 W
PSB
7 W
7 W
PCK
20 W
20 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.48 kW
0.79 kW
Annual energy consumption Qhe
2603 kWh
3633 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
129.3 %
COP
3.05
Heating up time
01:49 h:min
Standby power input
41 W
Reference hot water temperature
55.5 °C
Mixed water at 40°C
330 l