Certificate holders

Subtype

Grant Aerona HPR290155

Certificate Holder
Grant Engineering (UK) Ltd
Frankland Road Blagrove
SN5 8YG Swindon
United Kingdom
Registration number
041-K006-09
Certification Body
BRE Global Limited
Subtype title
Grant Aerona HPR290155
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,650 kg

Certification Date
14.01.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Grant Aerona HPR290155
Configure model
Model name
Grant Aerona HPR290155
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.16 kW

16.34 kW

El input

3.43 kW

5.69 kW

COP

4.72

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

133 %

Prated

14.8 kW

14 kW

SCOP

4.63

3.4

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.09 kW

12.4 kW

COP Tj = -7°C

2.67

1.82

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8.79 kW

7.71 kW

COP Tj = +2°C

4.72

3.39

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.79 kW

5.19 kW

COP Tj = +7°C

6.21

4.73

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.22 kW

4.63 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.2 kW

12.4 kW

COP Tj = Tbiv

2.67

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.79 kW

11.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.2

1.9

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

30 W

30 W

PSB

9 W

9 W

PCK

19 W

19 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

2.04 kW

Annual energy consumption Qhe

6605 kWh

8505 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118.2 %

COP

2.74

Heating up time

01:39 h:min

Standby power input

58 W

Reference hot water temperature

55.7 °C

Mixed water at 40°C

333 l