Certificate holders

Subtype

Grant Aerona HPR290155

Certificate Holder
Grant Engineering (UK) Ltd
Frankland Road Blagrove
SN5 8YG Swindon
United Kingdom
Registration number
041-K006-09
Certification Body
BRE
Subtype title
Grant Aerona HPR290155
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,650 kg

Certification Date
14.01.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Grant Aerona HPR290155
Configure model
Model name
Grant Aerona HPR290155
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

16.16 kW

16.34 kW

El input

3.43 kW

5.69 kW

COP

4.72

2.87

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

53 dB(A)

53 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

182 %

133 %

Prated

14.8 kW

14 kW

SCOP

4.63

3.4

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

13.09 kW

12.4 kW

COP Tj = -7°C

2.67

1.82

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

8.79 kW

7.71 kW

COP Tj = +2°C

4.72

3.39

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

5.79 kW

5.19 kW

COP Tj = +7°C

6.21

4.73

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

4.22 kW

4.63 kW

COP Tj = 12°C

7.82

6.56

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

13.2 kW

12.4 kW

COP Tj = Tbiv

2.67

1.82

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

12.79 kW

11.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.2

1.9

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

9 W

9 W

PTO

30 W

30 W

PSB

9 W

9 W

PCK

19 W

19 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.86 kW

2.04 kW

Annual energy consumption Qhe

6605 kWh

8505 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Declared load profile

L

Efficiency ηDHW

118.2 %

COP

2.74

Heating up time

01:39 h:min

Standby power input

58 W

Reference hot water temperature

55.7 °C

Mixed water at 40°C

333 l