1,650 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.16 kW
16.34 kW
El input
3.43 kW
5.69 kW
COP
4.72
2.87
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
133 %
Prated
14.8 kW
14 kW
SCOP
4.63
3.4
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
13.09 kW
12.4 kW
COP Tj = -7°C
2.67
1.82
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
8.79 kW
7.71 kW
COP Tj = +2°C
4.72
3.39
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
5.79 kW
5.19 kW
COP Tj = +7°C
6.21
4.73
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
4.22 kW
4.63 kW
COP Tj = 12°C
7.82
6.56
Cdh Tj = +12 °C
0.9
0.9
Pdh Tj = Tbiv
13.2 kW
12.4 kW
COP Tj = Tbiv
2.67
1.82
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
12.79 kW
11.79 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.2
1.9
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
9 W
9 W
PTO
30 W
30 W
PSB
9 W
9 W
PCK
19 W
19 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.86 kW
2.04 kW
Annual energy consumption Qhe
6605 kWh
8505 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
118.2 %
COP
2.74
Heating up time
01:39 h:min
Standby power input
58 W
Reference hot water temperature
55.7 °C
Mixed water at 40°C
333 l