Certificate holders

Subtype

Inverter Air to Water Heat Pump- R290- 17

Certificate Holder
Kyung Dong Navien Co., Ltd.
95, Suworam-gil, Seotan-myeon, Pyeongtack-si
11704 Gyeonggi-do
South Korea
Registration number
041-K108-04
Certification Body
BRE Global Limited
Subtype title
Inverter Air to Water Heat Pump- R290- 17
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,400 kg

Certification Date
05.12.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 14
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

PEM750V017PGKC
Configure model
Model name
PEM750V017PGKC
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

17.01 kW

17.30 kW

El input

3.73 kW

5.64 kW

COP

4.57

3.07

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

63 dB(A)

63 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

192 %

141 %

Prated

14.71 kW

14.85 kW

SCOP

4.87

3.61

Tbiv

-7 °C

-7 °C

TOL

-25 °C

-25 °C

Pdh Tj = -7°C

13.01 kW

13.14 kW

COP Tj = -7°C

3.13

2.31

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

7.97 kW

8.11 kW

COP Tj = +2°C

4.83

3.53

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.17 kW

5.25 kW

COP Tj = +7°C

6.12

4.57

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

5.81 kW

5.60 kW

COP Tj = 12°C

8.32

6.58

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

13.01 kW

13.14 kW

COP Tj = Tbiv

3.13

2.31

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

14.39 kW

14.79 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.63

1.94

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

13 W

13 W

PTO

15 W

15 W

PSB

13 W

13 W

PCK

80 W

80 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.32 kW

0.06 kW

Annual energy consumption Qhe

6244 kWh

8502 kWh