2,200 kg
Heating
EN 14511-4
Operating range outdoor exchanger/indoor exchanger lower limit/lower limit
passed
Operating range outdoor exchanger/indoor exchanger upper limit/upper limit
passed
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
EN 14511-2
Low temperature
Medium temperature
Heat output
5.88 kW
4.67 kW
El input
1.16 kW
1.47 kW
COP
5.06
3.17
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
160 %
124 %
Prated
6.50 kW
6.50 kW
SCOP
4.08
3.17
Tbiv
-14 °C
-13 °C
TOL
-22 °C
-22 °C
Pdh Tj = -7°C
4.29 kW
4.04 kW
COP Tj = -7°C
3.61
2.66
Pdh Tj = +2°C
2.39 kW
2.34 kW
COP Tj = +2°C
5.08
4.11
Pdh Tj = +7°C
2.46 kW
2.44 kW
COP Tj = +7°C
6.00
5.08
Pdh Tj = 12°C
2.94 kW
2.86 kW
COP Tj = 12°C
7.13
6.08
Pdh Tj = Tbiv
5.15 kW
5.00 kW
COP Tj = Tbiv
2.52
1.91
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.95 kW
3.64 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
1.91
1.25
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.55 kW
2.86 kW
Annual energy consumption Qhe
3932 kWh
5052 kWh
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
53 dB(A)
53 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
189 %
143 %
Prated
6.00 kW
6.60 kW
SCOP
4.81
3.64
Tbiv
-9 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.61 kW
5.89 kW
COP Tj = -7°C
3.03
2.03
Pdh Tj = +2°C
3.46 kW
3.62 kW
COP Tj = +2°C
5.14
3.81
Pdh Tj = +7°C
2.45 kW
2.43 kW
COP Tj = +7°C
5.83
4.86
Pdh Tj = 12°C
2.92 kW
2.83 kW
COP Tj = 12°C
7.27
5.90
Pdh Tj = Tbiv
5.88 kW
5.89 kW
COP Tj = Tbiv
2.66
2.03
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.71 kW
5.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.77
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.98
0.98
WTOL
65 °C
65 °C
Poff
14 W
14 W
PTO
14 W
14 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.29 kW
1.27 kW
Annual energy consumption Qhe
2579 kWh
3743 kWh