Certificate holders

Subtype

Grant Aerona HPR2904

Certificate Holder
Grant Engineering (UK) Ltd
Frankland Road Blagrove
SN5 8YG Swindon
United Kingdom
Registration number
041-K006-05
Certification Body
BRE Global Limited
Subtype title
Grant Aerona HPR2904
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,610 kg

Certification Date
14.01.2025
Testing basis
Heat Pump Keymark Scheme Rules Rev 15
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Grant Aerona HPR2904
Configure model
Model name
Grant Aerona HPR2904
Application
Heating + DHW + low temp
Units
Outdoor
Climate Zone
n/a
Reversibility
No
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.09 kW

4.36 kW

El input

0.82 kW

1.36 kW

COP

4.99

3.19

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

32 dB(A)

33 dB(A)

Sound power level outdoor

47 dB(A)

48 dB(A)

EN 14825

Low temperature

Medium temperature

Pdesignh

4.09 kW

4.36 kW

ηs

200 %

146 %

Prated

4.09 kW

4.36 kW

SCOP

5.08

3.74

Tbiv

-8 °C

-8 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.78 kW

3.93 kW

COP Tj = -7°C

3.57

2.48

Cdh Tj = -7 °C

0.9

0.9

Pdh Tj = +2°C

2.4 kW

2.34 kW

COP Tj = +2°C

5.19

3.73

Cdh Tj = +2 °C

0.9

0.9

Pdh Tj = +7°C

1.7 kW

1.92 kW

COP Tj = +7°C

6.47

4.69

Cdh Tj = +7 °C

0.9

0.9

Pdh Tj = 12°C

1.35 kW

1.25 kW

COP Tj = 12°C

6.23

6.06

Cdh Tj = +12 °C

0.9

0.9

Pdh Tj = Tbiv

3.98 kW

3.93 kW

COP Tj = Tbiv

3.29

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.77 kW

3.8 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.05

2.21

Rated airflow rate

2300 m³/h

2300 m³/h

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.9

0.9

WTOL

60 °C

60 °C

Poff

7 W

7 W

PTO

21 W

21 W

PSB

7 W

7 W

PCK

20 W

20 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.3 kW

0.52 kW

Annual energy consumption Qhe

1664 kWh

2411 kWh

Domestic Hot Water (DHW)

Average Climate

EN 16147

Medium temperature

Declared load profile

L

Large

Efficiency ηDHW

132 %

132 %

COP

3.11

3.11

Heating up time

03:08 h:min

03:08 h:min

Standby power input

40 W

40 W

Reference hot water temperature

55 °C

55 °C

Mixed water at 40°C

330 l

330 l