0,610 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.09 kW
4.36 kW
El input
0.82 kW
1.36 kW
COP
4.99
3.19
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
32 dB(A)
33 dB(A)
Sound power level outdoor
47 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
Pdesignh
4.09 kW
4.36 kW
ηs
200 %
146 %
Prated
4.09 kW
4.36 kW
SCOP
5.08
3.74
Tbiv
-8 °C
-8 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.78 kW
3.93 kW
COP Tj = -7°C
3.57
2.48
Cdh Tj = -7 °C
0.9
0.9
Pdh Tj = +2°C
2.4 kW
2.34 kW
COP Tj = +2°C
5.19
3.73
Cdh Tj = +2 °C
0.9
0.9
Pdh Tj = +7°C
1.7 kW
1.92 kW
COP Tj = +7°C
6.47
4.69
Cdh Tj = +7 °C
0.9
0.9
Pdh Tj = 12°C
1.35 kW
1.25 kW
COP Tj = 12°C
6.23
6.06
Cdh Tj = +12 °C
0.9
0.9
Pdh Tj = Tbiv
3.98 kW
3.93 kW
COP Tj = Tbiv
3.29
2.32
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.77 kW
3.8 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.05
2.21
Rated airflow rate
2300 m³/h
2300 m³/h
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.9
0.9
WTOL
60 °C
60 °C
Poff
7 W
7 W
PTO
21 W
21 W
PSB
7 W
7 W
PCK
20 W
20 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.3 kW
0.52 kW
Annual energy consumption Qhe
1664 kWh
2411 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Medium temperature
Declared load profile
L
Large
Efficiency ηDHW
132 %
132 %
COP
3.11
3.11
Heating up time
03:08 h:min
03:08 h:min
Standby power input
40 W
40 W
Reference hot water temperature
55 °C
55 °C
Mixed water at 40°C
330 l
330 l