1,300 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.71 kW
1.73 kW
COP
5.01
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
245 %
165 %
Prated
3.22 kW
4.02 kW
SCOP
6.20
4.20
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
4.15
2.50
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.66
3.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.90
5.50
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
4.15
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
694 kWh
1278 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.41 kW
2.98 kW
SCOP
4.04
2.80
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.54
2.43
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.82
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
6.31
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
8.02
6.43
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.64
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2080 kWh
2629 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.64
1.75
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
129 %
Prated
3.44 kW
3.65 kW
SCOP
4.79
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.25
2.15
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.71
3.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
6.10
4.32
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
8.20
6.20
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.25
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1487 kWh
2277 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.71 kW
1.73 kW
COP
5.01
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
245 %
165 %
Prated
3.22 kW
4.02 kW
SCOP
6.20
4.20
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
4.15
2.50
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.66
3.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.90
5.50
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
4.15
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
694 kWh
1278 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.41 kW
2.98 kW
SCOP
4.04
2.80
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.54
2.43
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.82
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
6.31
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
8.02
6.43
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.64
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2080 kWh
2629 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.64
1.75
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
129 %
Prated
3.44 kW
3.65 kW
SCOP
4.79
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.25
2.15
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.71
3.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
6.10
4.32
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
8.20
6.20
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.25
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1487 kWh
2277 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.75 kW
1.78 kW
COP
4.71
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.77 kW
1.30 kW
Cooling capacity
5.22
5.31
EER
2.95
4.08
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.33
6.33
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.13
3.99
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
3.76
5.59
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
4.89
7.44
Cdc Tj = 25 °C
0.975
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.19
9.29
Cdc Tj = 20 °C
0.971
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
537 kWh
492 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
220 %
153 %
Prated
3.22 kW
4.02 kW
SCOP
5.58
3.91
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
3.93
2.43
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.11
3.37
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.02
5.02
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
3.93
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.93
2.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
771 kWh
1372 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
146 %
102 %
Prated
3.41 kW
2.98 kW
SCOP
3.72
2.63
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.31
2.30
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.35
3.25
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
5.63
4.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
7.10
5.79
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.53
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2256 kWh
2796 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.53
1.69
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
171 %
121 %
Prated
3.44 kW
3.65 kW
SCOP
4.36
3.10
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.10
2.09
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.27
3.00
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
5.48
3.96
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
7.24
5.62
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.10
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1632 kWh
2431 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.71 kW
1.73 kW
COP
5.01
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
225 %
157 %
Prated
3.22 kW
4.02 kW
SCOP
5.69
4.00
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
4.15
2.50
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.66
3.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.90
5.50
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
4.15
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
756 kWh
1340 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
156 %
108 %
Prated
3.41 kW
2.98 kW
SCOP
3.98
2.76
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.54
2.43
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.82
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
6.31
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
8.02
6.43
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.64
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2111 kWh
2660 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.64
1.75
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
127 %
Prated
3.44 kW
3.65 kW
SCOP
4.63
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.25
2.15
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.71
3.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
6.10
4.32
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
8.20
6.20
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.25
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1538 kWh
2328 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.75 kW
1.78 kW
COP
4.71
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
204 %
147 %
Prated
3.22 kW
4.02 kW
SCOP
5.16
3.74
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
3.93
2.43
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.11
3.37
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.02
5.02
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
3.93
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.93
2.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
62 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
833 kWh
1434 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
144 %
101 %
Prated
3.41 kW
2.98 kW
SCOP
3.67
2.60
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.31
2.30
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.35
3.25
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
5.63
4.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
7.10
5.79
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.53
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
62 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2287 kWh
2827 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.53
1.69
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
166 %
118 %
Prated
3.44 kW
3.65 kW
SCOP
4.23
3.04
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.10
2.09
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.27
3.00
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
5.48
3.96
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
7.24
5.62
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.10
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
62 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1683 kWh
2483 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.71 kW
1.73 kW
COP
5.01
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
245 %
165 %
Prated
3.22 kW
4.02 kW
SCOP
6.20
4.20
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
4.15
2.50
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.66
3.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.90
5.50
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
4.15
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
694 kWh
1278 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.41 kW
2.98 kW
SCOP
4.04
2.80
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.54
2.43
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.82
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
6.31
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
8.02
6.43
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.64
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2080 kWh
2629 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.64
1.75
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
129 %
Prated
3.44 kW
3.65 kW
SCOP
4.79
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.25
2.15
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.71
3.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
6.10
4.32
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
8.20
6.20
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.25
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1487 kWh
2277 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.71 kW
1.73 kW
COP
5.01
2.89
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
245 %
165 %
Prated
3.22 kW
4.02 kW
SCOP
6.20
4.20
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
4.15
2.50
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.66
3.58
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.90
5.50
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
4.15
2.50
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
4.15
2.50
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
694 kWh
1278 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
158 %
109 %
Prated
3.41 kW
2.98 kW
SCOP
4.04
2.80
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.54
2.43
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.82
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
6.31
4.77
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
8.02
6.43
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.64
1.75
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.27
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2080 kWh
2629 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.64
1.75
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
188 %
129 %
Prated
3.44 kW
3.65 kW
SCOP
4.79
3.31
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.25
2.15
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.71
3.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
6.10
4.32
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
8.20
6.20
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.25
2.15
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.93
1.81
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1487 kWh
2277 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
3.54 kW
5.00 kW
El input
0.75 kW
1.78 kW
COP
4.71
2.81
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.77 kW
1.30 kW
Cooling capacity
5.22
5.31
EER
2.95
4.08
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.33
6.33
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.13
3.99
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
3.76
5.59
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
4.89
7.44
Cdc Tj = 25 °C
0.975
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.19
9.29
Cdc Tj = 20 °C
0.971
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
537 kWh
492 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
220 %
153 %
Prated
3.22 kW
4.02 kW
SCOP
5.58
3.91
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
3.22 kW
4.02 kW
COP Tj = +2°C
3.93
2.43
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.35 kW
2.66 kW
COP Tj = +7°C
5.11
3.37
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.82 kW
2.58 kW
COP Tj = 12°C
7.02
5.02
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.22 kW
4.02 kW
COP Tj = Tbiv
3.93
2.43
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.22 kW
4.02 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.93
2.43
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
771 kWh
1372 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
146 %
102 %
Prated
3.41 kW
2.98 kW
SCOP
3.72
2.63
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
2.26 kW
1.95 kW
COP Tj = -7°C
3.31
2.30
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.04 kW
1.86 kW
COP Tj = +2°C
4.35
3.25
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.34 kW
2.22 kW
COP Tj = +7°C
5.63
4.35
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.78 kW
2.65 kW
COP Tj = 12°C
7.10
5.79
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
2.78 kW
2.43 kW
COP Tj = Tbiv
2.53
1.69
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.33 kW
2.43 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.17
1.69
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
3.41 kW
2.98 kW
Annual energy consumption Qhe
2256 kWh
2796 kWh
Pdh Tj = -15°C (if TOL<-20°C)
2.78
2.43
COP Tj = -15°C (if TOL<-20°C)
2.53
1.69
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
171 %
121 %
Prated
3.44 kW
3.65 kW
SCOP
4.36
3.10
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.05 kW
3.23 kW
COP Tj = -7°C
3.10
2.09
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
2.09 kW
COP Tj = +2°C
4.27
3.00
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.41 kW
2.14 kW
COP Tj = +7°C
5.48
3.96
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.76 kW
2.71 kW
COP Tj = 12°C
7.24
5.62
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
3.05 kW
3.23 kW
COP Tj = Tbiv
3.10
2.09
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.03 kW
2.75 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.75
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.42 kW
0.90 kW
Annual energy consumption Qhe
1632 kWh
2431 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.92 kW
1.89 kW
COP
4.89
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
170 %
Prated
5.01 kW
4.68 kW
SCOP
6.37
4.32
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.54
2.26
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.84
3.59
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.91
5.92
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.54
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1050 kWh
1447 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
111 %
Prated
5.44 kW
3.97 kW
SCOP
4.13
2.86
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.54
2.51
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
5.02
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
6.67
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.95
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.57
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3244 kWh
3423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.57
1.84
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
129 %
Prated
4.72 kW
4.35 kW
SCOP
4.87
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.13
2.10
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.84
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
6.24
4.39
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
8.04
6.03
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.13
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2003 kWh
2727 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.92 kW
1.89 kW
COP
4.89
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
170 %
Prated
5.01 kW
4.68 kW
SCOP
6.37
4.32
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.54
2.26
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.84
3.59
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.91
5.92
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.54
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1050 kWh
1447 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
111 %
Prated
5.44 kW
3.97 kW
SCOP
4.13
2.86
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.54
2.51
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
5.02
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
6.67
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.95
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.57
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3244 kWh
3423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.57
1.84
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
129 %
Prated
4.72 kW
4.35 kW
SCOP
4.87
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.13
2.10
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.84
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
6.24
4.39
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
8.04
6.03
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.13
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2003 kWh
2727 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.97 kW
1.94 kW
COP
4.66
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.77 kW
1.30 kW
Cooling capacity
5.22
5.31
EER
2.95
4.08
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.33
6.33
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.13
3.99
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
3.76
5.59
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
4.89
7.44
Cdc Tj = 25 °C
0.975
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.19
9.29
Cdc Tj = 20 °C
0.971
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
537 kWh
492 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
158 %
Prated
5.01 kW
4.68 kW
SCOP
5.78
4.03
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.43
2.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.37
3.40
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.02
5.39
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.43
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.43
2.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1156 kWh
1551 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
105 %
Prated
5.44 kW
3.97 kW
SCOP
3.84
2.69
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.38
2.39
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
4.51
3.25
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
5.94
4.42
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.06
5.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.51
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.12
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3488 kWh
3629 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.51
1.79
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
121 %
Prated
4.72 kW
4.35 kW
SCOP
4.50
3.09
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.03
2.05
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.48
2.98
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
5.60
4.03
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
7.13
5.48
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.03
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2169 kWh
2905 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.97 kW
1.94 kW
COP
4.66
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
217 %
152 %
Prated
5.01 kW
4.68 kW
SCOP
5.49
3.88
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.43
2.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.37
3.40
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.02
5.39
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.43
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.43
2.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1218 kWh
1613 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
149 %
104 %
Prated
5.44 kW
3.97 kW
SCOP
3.81
2.67
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.38
2.39
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
4.51
3.25
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
5.94
4.42
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.06
5.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.51
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.12
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3519 kWh
3660 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.51
1.79
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
173 %
119 %
Prated
4.72 kW
4.35 kW
SCOP
4.39
3.04
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.03
2.05
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.48
2.98
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
5.60
4.03
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
7.13
5.48
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.03
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2220 kWh
2956 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.92 kW
1.89 kW
COP
4.89
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
170 %
Prated
5.01 kW
4.68 kW
SCOP
6.37
4.32
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.54
2.26
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.84
3.59
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.91
5.92
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.54
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1050 kWh
1447 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
111 %
Prated
5.44 kW
3.97 kW
SCOP
4.13
2.86
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.54
2.51
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
5.02
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
6.67
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.95
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.57
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3244 kWh
3423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.57
1.84
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
129 %
Prated
4.72 kW
4.35 kW
SCOP
4.87
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.13
2.10
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.84
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
6.24
4.39
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
8.04
6.03
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.13
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2003 kWh
2727 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.92 kW
1.89 kW
COP
4.89
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.73 kW
1.26 kW
Cooling capacity
5.22
5.31
EER
3.03
4.22
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.69
6.94
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.25
4.13
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
4.01
5.98
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
5.41
8.34
Cdc Tj = 25 °C
0.969
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.97
10.65
Cdc Tj = 20 °C
0.963
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
496 kWh
449 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
252 %
170 %
Prated
5.01 kW
4.68 kW
SCOP
6.37
4.32
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.54
2.26
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.84
3.59
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.91
5.92
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.54
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1050 kWh
1447 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
162 %
111 %
Prated
5.44 kW
3.97 kW
SCOP
4.13
2.86
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.54
2.51
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
5.02
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
6.67
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.95
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.57
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3244 kWh
3423 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.57
1.84
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
192 %
129 %
Prated
4.72 kW
4.35 kW
SCOP
4.87
3.30
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.13
2.10
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.84
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
6.24
4.39
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
8.04
6.03
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.13
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2003 kWh
2727 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.97 kW
1.94 kW
COP
4.66
2.76
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Cooling
EN 14511-2
+7°C/+12°C
+18°C/+23°C
El input
1.77 kW
1.30 kW
Cooling capacity
5.22
5.31
EER
2.95
4.08
EN 14825
+7°C/+12°C
+18°C/+23°C
Pdesignc
3.88 kW
5.19 kW
SEER
4.33
6.33
Pdc Tj = 35°C
3.88 kW
5.19 kW
EER Tj = 35°C
3.13
3.99
Cdc Tj = 35 °C
1.000
1.000
Pdc Tj = 30°C
2.64 kW
3.81 kW
EER Tj = 30°C
3.76
5.59
Cdc Tj = 30 °C
1.000
1.000
Pdc Tj = 25°C
2.28 kW
3.11 kW
EER Tj = 25°C
4.89
7.44
Cdc Tj = 25 °C
0.975
0.965
Pdc Tj = 20°C
2.50 kW
3.27 kW
EER Tj = 20°C
6.19
9.29
Cdc Tj = 20 °C
0.971
0.957
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Annual energy consumption Qce
537 kWh
492 kWh
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
228 %
158 %
Prated
5.01 kW
4.68 kW
SCOP
5.78
4.03
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.43
2.21
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.37
3.40
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.02
5.39
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.43
2.21
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.43
2.21
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1156 kWh
1551 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
151 %
105 %
Prated
5.44 kW
3.97 kW
SCOP
3.84
2.69
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.38
2.39
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
4.51
3.25
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
5.94
4.42
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.06
5.74
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.51
1.79
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.12
1.79
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3488 kWh
3629 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.51
1.79
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
177 %
121 %
Prated
4.72 kW
4.35 kW
SCOP
4.50
3.09
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.03
2.05
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.48
2.98
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
5.60
4.03
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
7.13
5.48
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.03
2.05
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.72
1.62
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2169 kWh
2905 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.51 kW
5.36 kW
El input
0.92 kW
1.89 kW
COP
4.89
2.83
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Warmer Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
238 %
163 %
Prated
5.01 kW
4.68 kW
SCOP
6.01
4.15
Tbiv
2 °C
2 °C
TOL
2 °C
2 °C
Pdh Tj = +2°C
5.01 kW
4.68 kW
COP Tj = +2°C
3.54
2.26
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
3.00 kW
2.95 kW
COP Tj = +7°C
5.84
3.59
Cdh Tj = +7 °C
0.97
0.98
Pdh Tj = 12°C
2.81 kW
2.67 kW
COP Tj = 12°C
7.91
5.92
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
5.01 kW
4.68 kW
COP Tj = Tbiv
3.54
2.26
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
5.01 kW
4.68 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
3.54
2.26
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.00 kW
0.00 kW
Annual energy consumption Qhe
1112 kWh
1509 kWh
Colder Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
41 dB(A)
41 dB(A)
Sound power level outdoor
48 dB(A)
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
161 %
110 %
Prated
5.44 kW
3.97 kW
SCOP
4.09
2.83
Tbiv
-15 °C
-15 °C
TOL
-20 °C
-15 °C
Pdh Tj = -7°C
3.46 kW
2.27 kW
COP Tj = -7°C
3.54
2.51
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.02 kW
1.86 kW
COP Tj = +2°C
5.02
3.53
Cdh Tj = +2 °C
0.97
0.98
Pdh Tj = +7°C
2.42 kW
2.28 kW
COP Tj = +7°C
6.67
4.84
Cdh Tj = +7 °C
0.96
0.97
Pdh Tj = 12°C
2.83 kW
2.73 kW
COP Tj = 12°C
7.95
6.34
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.43 kW
3.23 kW
COP Tj = Tbiv
2.57
1.84
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
2.99 kW
3.23 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.19
1.84
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
5.44 kW
3.97 kW
Annual energy consumption Qhe
3275 kWh
3454 kWh
Pdh Tj = -15°C (if TOL<-20°C)
4.43
3.23
COP Tj = -15°C (if TOL<-20°C)
2.57
1.84
Cdh Tj = -15 °C
1.00
1.00
Average Climate
EN 12102-1
Medium temperature
Sound power level indoor
n/a
41 dB(A)
Sound power level outdoor
n/a
48 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
187 %
126 %
Prated
4.72 kW
4.35 kW
SCOP
4.75
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
4.18 kW
3.85 kW
COP Tj = -7°C
3.13
2.10
Cdh Tj = -7 °C
1.00
1.00
Pdh Tj = +2°C
2.67 kW
2.13 kW
COP Tj = +2°C
4.84
3.18
Cdh Tj = +2 °C
1.00
1.00
Pdh Tj = +7°C
2.43 kW
2.21 kW
COP Tj = +7°C
6.24
4.39
Cdh Tj = +7 °C
0.97
0.97
Pdh Tj = 12°C
2.84 kW
2.72 kW
COP Tj = 12°C
8.04
6.03
Cdh Tj = +12 °C
0.96
0.97
Pdh Tj = Tbiv
4.18 kW
3.85 kW
COP Tj = Tbiv
3.13
2.10
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.06 kW
3.33 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
1.66
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
1.00
1.00
WTOL
60 °C
60 °C
Poff
14 W
14 W
PTO
13 W
13 W
PSB
14 W
14 W
PCK
0 W
0 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.66 kW
1.02 kW
Annual energy consumption Qhe
2055 kWh
2778 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
141 %
COP
3.53
Heating up time
01:19 h:min
Standby power input
46.1 W
Reference hot water temperature
52.4 °C
Mixed water at 40°C
249 l