1,400 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
4.20 kW
4.00 kW
El input
0.86 kW
1.53 kW
COP
4.89
2.62
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
55 dB(A)
56 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
184 %
128 %
Prated
4.00 kW
4.60 kW
SCOP
4.64
3.24
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
3.54 kW
4.07 kW
COP Tj = -7°C
3.17
2.12
Cdh Tj = -7 °C
0.980
0.990
Pdh Tj = +2°C
2.65 kW
2.51 kW
COP Tj = +2°C
4.78
2.99
Cdh Tj = +2 °C
0.960
0.980
Pdh Tj = +7°C
2.69 kW
2.42 kW
COP Tj = +7°C
5.91
4.61
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
2.60 kW
2.52 kW
COP Tj = 12°C
8.29
6.38
Cdh Tj = +12 °C
0.920
0.940
Pdh Tj = Tbiv
3.54 kW
4.07 kW
COP Tj = Tbiv
3.17
2.12
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
3.24 kW
3.81 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
1.80
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.980
0.990
WTOL
60 °C
60 °C
Poff
7 W
7 W
PTO
20 W
20 W
PSB
7 W
7 W
PCK
21 W
21 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
0.76 kW
0.79 kW
Annual energy consumption Qhe
1776 kWh
2838 kWh
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
6.00 kW
6.20 kW
El input
1.23 kW
2.18 kW
COP
4.89
2.84
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
42 dB(A)
42 dB(A)
Sound power level outdoor
57 dB(A)
58 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
182 %
130 %
Prated
5.90 kW
5.60 kW
SCOP
4.61
3.33
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
5.21 kW
4.96 kW
COP Tj = -7°C
2.99
2.04
Cdh Tj = -7 °C
0.990
0.990
Pdh Tj = +2°C
3.31 kW
3.09 kW
COP Tj = +2°C
4.54
3.32
Cdh Tj = +2 °C
0.970
0.980
Pdh Tj = +7°C
2.81 kW
2.35 kW
COP Tj = +7°C
6.03
4.35
Cdh Tj = +7 °C
0.950
0.960
Pdh Tj = 12°C
2.58 kW
2.74 kW
COP Tj = 12°C
8.41
6.18
Cdh Tj = +12 °C
0.920
0.940
Pdh Tj = Tbiv
5.21 kW
4.96 kW
COP Tj = Tbiv
2.99
2.04
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
4.86 kW
4.30 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.60
1.72
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.990
0.990
WTOL
60 °C
60 °C
Poff
7 W
7 W
PTO
20 W
20 W
PSB
7 W
7 W
PCK
21 W
21 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.02 kW
1.31 kW
Annual energy consumption Qhe
2634 kWh
3482 kWh