1,600 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
10.78 kW
12.00 kW
El input
2.42 kW
3.86 kW
COP
4.46
3.11
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level indoor
36 dB(A)
37 dB(A)
Sound power level outdoor
57 dB(A)
57 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
180 %
140 %
Prated
12.06 kW
11.92 kW
SCOP
4.56
3.58
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
10.67 kW
10.54 kW
COP Tj = -7°C
2.89
2.45
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
7.05 kW
6.99 kW
COP Tj = +2°C
4.81
3.67
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
6.28 kW
5.86 kW
COP Tj = +7°C
5.71
4.35
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
7.40 kW
6.88 kW
COP Tj = 12°C
7.46
6.34
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
10.67 kW
10.54 kW
COP Tj = Tbiv
2.89
2.45
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
10.05 kW
9.01 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.74
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
10 W
10 W
PTO
17 W
17 W
PSB
10 W
10 W
PCK
62 W
62 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
2.01 kW
2.91 kW
Annual energy consumption Qhe
5458 kWh
6878 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
XL
Efficiency ηDHW
124 %
COP
3.10
Heating up time
1:25:22 h:min
Standby power input
33.0 W
Reference hot water temperature
45.2 °C
Mixed water at 40°C
229 l