0,900 kg
Heating
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 14825
Low temperature
Medium temperature
ηs
186 %
142 %
Prated
9.42 kW
8.60 kW
SCOP
4.73
3.62
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
8.33 kW
7.60 kW
COP Tj = -7°C
3.10
2.31
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
5.05 kW
4.82 kW
COP Tj = +2°C
4.79
3.65
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
4.42 kW
4.19 kW
COP Tj = +7°C
6.21
4.72
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
5.17 kW
4.95 kW
COP Tj = 12°C
8.06
6.28
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
8.33 kW
7.60 kW
COP Tj = Tbiv
3.10
2.31
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
7.53 kW
7.18 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.81
2.06
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
12 W
12 W
PTO
21 W
21 W
PSB
12 W
12 W
PCK
26 W
26 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.88 kW
1.41 kW
Annual energy consumption Qhe
4115 kWh
4911 kWh
Domestic Hot Water (DHW)
Average Climate
EN 16147
Declared load profile
L
Efficiency ηDHW
115 %
COP
2.88
Heating up time
1:59:42 h:min
Standby power input
35.0 W
Reference hot water temperature
44.8 °C
Mixed water at 40°C
227 l