Certificate holders

Subtype

Air to Water Heat Pump Unit- R290-4

Certificate Holder
Hisense Air Conditioning Co. Ltd.
No. 1 Hisense Road, Nancun Town Pingdu
266736 Qingdao, Shandong Province
China
Registration number
041-K100-05
Certification Body
BRE Global Limited
Subtype title
Air to Water Heat Pump Unit- R290-4
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,600 kg

Certification Date
27.11.2024
Testing basis
HP KEYMARK certification scheme rules rev. no.15
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AHZ-040U4GSA00
Configure model
Model name
AHZ-040U4GSA00
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.05 kW

4.01 kW

El input

0.82 kW

1.27 kW

COP

4.94

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

138 %

Prated

3.59 kW

3.53 kW

SCOP

4.72

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.17 kW

3.12 kW

COP Tj = -7°C

3.24

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

1.96 kW

2.01 kW

COP Tj = +2°C

4.43

3.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.41 kW

1.46 kW

COP Tj = +7°C

6.42

4.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.73 kW

1.61 kW

COP Tj = 12°C

8.74

6.73

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.17 kW

3.12 kW

COP Tj = Tbiv

3.24

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.65 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

22 W

22 W

PSB

10 W

10 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1571 kWh

2074 kWh