Certificate holders

Subtype

Air to Water Heat Pump Unit- R290-4

Certificate Holder
Hisense Air Conditioning Co. Ltd.
No. 1 Hisense Road, Nancun Town Pingdu
266736 Qingdao, Shandong Province
China
Registration number
041-K100-05
Certification Body
BRE
Subtype title
Air to Water Heat Pump Unit- R290-4
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,600 kg

Certification Date
27.11.2024
Testing basis
HP KEYMARK certification scheme rules rev. no.15
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

AHZ-040U4GSA00
Configure model
Model name
AHZ-040U4GSA00
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.05 kW

4.01 kW

El input

0.82 kW

1.27 kW

COP

4.94

3.17

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

50 dB(A)

51 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

186 %

138 %

Prated

3.59 kW

3.53 kW

SCOP

4.72

3.52

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

3.17 kW

3.12 kW

COP Tj = -7°C

3.24

2.40

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

1.96 kW

2.01 kW

COP Tj = +2°C

4.43

3.27

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.41 kW

1.46 kW

COP Tj = +7°C

6.42

4.82

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.73 kW

1.61 kW

COP Tj = 12°C

8.74

6.73

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.17 kW

3.12 kW

COP Tj = Tbiv

3.24

2.40

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.65 kW

3.54 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.90

2.16

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

22 W

22 W

PSB

10 W

10 W

PCK

40 W

40 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1571 kWh

2074 kWh