1,800 kg
Heating
EN 14511-2
Low temperature
Medium temperature
Heat output
16.35 kW
18.79 kW
El input
3.33 kW
6.67 kW
COP
4.91
2.82
EN 14511-4
Shutting off the heat transfer medium flow
passed
Complete power supply failure
passed
Defrost test
passed
Starting and operating test
passed
Average Climate
EN 12102-1
Low temperature
Medium temperature
Sound power level outdoor
63 dB(A)
61 dB(A)
EN 14825
Low temperature
Medium temperature
ηs
186 %
142 %
Prated
18.37 kW
17.37 kW
SCOP
4.73
3.63
Tbiv
-7 °C
-7 °C
TOL
-10 °C
-10 °C
Pdh Tj = -7°C
16.25 kW
15.36 kW
COP Tj = -7°C
2.91
2.16
Cdh Tj = -7 °C
0.900
0.900
Pdh Tj = +2°C
10.02 kW
9.59 kW
COP Tj = +2°C
4.58
3.58
Cdh Tj = +2 °C
0.900
0.900
Pdh Tj = +7°C
9.29 kW
8.84 kW
COP Tj = +7°C
6.83
5.11
Cdh Tj = +7 °C
0.900
0.900
Pdh Tj = 12°C
10.49 kW
10.05 kW
COP Tj = 12°C
8.97
7.05
Cdh Tj = +12 °C
0.900
0.900
Pdh Tj = Tbiv
16.25 kW
15.36 kW
COP Tj = Tbiv
2.91
2.16
Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
16.49 kW
15.71 kW
COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh
2.59
1.92
Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh
0.900
0.900
WTOL
75 °C
75 °C
Poff
20 W
20 W
PTO
21 W
21 W
PSB
20 W
20 W
PCK
43 W
43 W
Supplementary Heater: Type of energy input
Electricity
Electricity
Supplementary Heater: PSUP
1.88 kW
1.66 kW
Annual energy consumption Qhe
8023 kWh
9873 kWh