Certificate holders

Subtype

Acond Aconomis N

Certificate Holder
Acond a.s.
Štěrboholská 1434/102a
102 00 Hostivař, Praha
Czech Republic
Registration number
037-0184-24 / rev. 1
Certification Body
SZU - Strojirensky zkusebni ustav (Engineering Test Institute, Public Enterprise)
Subtype title
Acond Aconomis N
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,100 kg

Certification Date
08.07.2024
Testing basis
HP Keymark certification scheme rules rev. no.14
Testing laboratory
SZU Brno, CZ
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

Acond Aconomis N
Configure model
Model name
Acond Aconomis N
Application
Heating (medium temp)
Units
Indoor + Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.76 kW

4.10 kW

El input

0.96 kW

1.33 kW

COP

4.95

3.08

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

240 %

170 %

Prated

6.50 kW

6.10 kW

SCOP

6.06

4.33

Tbiv

2 °C

2 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

6.51 kW

6.05 kW

COP Tj = +2°C

3.48

2.47

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

4.19 kW

3.89 kW

COP Tj = +7°C

5.46

3.88

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.41 kW

2.33 kW

COP Tj = 12°C

7.44

5.30

Cdh Tj = +12 °C

0.954

0.966

Pdh Tj = Tbiv

6.51 kW

6.05 kW

COP Tj = Tbiv

3.48

2.47

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.51 kW

6.05 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.48

2.47

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.00 kW

Annual energy consumption Qhe

1434 kWh

1869 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

152 %

121 %

Prated

10.50 kW

11.40 kW

SCOP

3.87

3.10

Tbiv

-7 °C

-7 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

6.37 kW

6.88 kW

COP Tj = -7°C

3.33

2.57

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.88 kW

4.19 kW

COP Tj = +2°C

5.13

4.12

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.49 kW

2.69 kW

COP Tj = +7°C

7.06

5.47

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.41 kW

2.36 kW

COP Tj = 12°C

7.44

6.40

Cdh Tj = +12 °C

0.954

0.959

Pdh Tj = Tbiv

6.37 kW

6.88 kW

COP Tj = Tbiv

3.33

2.57

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

4.81 kW

4.42 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.52

1.92

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

5.69 kW

6.98 kW

Annual energy consumption Qhe

6707 kWh

9026 kWh

Pdh Tj = -15°C (if TOL<-20°C)

5.68

5.23

COP Tj = -15°C (if TOL<-20°C)

2.77

2.17

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level indoor

0 dB(A)

0 dB(A)

Sound power level outdoor

0 dB(A)

54 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

188 %

150 %

Prated

7.65 kW

7.50 kW

SCOP

4.77

3.82

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

6.78 kW

6.58 kW

COP Tj = -7°C

3.05

2.29

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

4.05 kW

4.00 kW

COP Tj = +2°C

4.64

3.81

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.65 kW

2.57 kW

COP Tj = +7°C

6.37

4.98

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.41 kW

2.38 kW

COP Tj = 12°C

7.44

5.98

Cdh Tj = +12 °C

0.954

0.962

Pdh Tj = Tbiv

6.78 kW

6.58 kW

COP Tj = Tbiv

3.05

2.29

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

6.12 kW

6.03 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.91

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

15 W

15 W

PSB

15 W

15 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.53 kW

1.47 kW

Annual energy consumption Qhe

3320 kWh

4025 kWh