Certificate holders

Subtype

Air to water heat pump- R290- 130T- PA

Certificate Holder
Guangdong New Energy Technology Co., Ltd.
NO.125, Chuangyou Road
511340 Guangdong
China
Registration number
041-K054-16
Certification Body
BRE Global Limited
Subtype title
Air to water heat pump- R290- 130T- PA
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

1,050 kg

Certification Date
29.11.2024
Testing basis
HP KEYMARK certification scheme rules rev. no.14
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

NE-F130HCR5TINVMV2-PA
Configure model
Model name
NE-F130HCR5TINVMV2-PA
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
3x400V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

7.76 kW

7.94 kW

El input

1.56 kW

2.54 kW

COP

4.98

3.13

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

55 dB(A)

55 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

199 %

149 %

Prated

9.96 kW

9.87 kW

SCOP

5.05

3.80

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

8.81 kW

8.73 kW

COP Tj = -7°C

3.37

2.41

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

5.45 kW

5.35 kW

COP Tj = +2°C

4.97

3.72

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

5.40 kW

4.06 kW

COP Tj = +7°C

6.87

5.01

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

6.32 kW

4.88 kW

COP Tj = 12°C

8.70

6.89

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

8.81 kW

8.73 kW

COP Tj = Tbiv

3.37

2.41

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

9.73 kW

10.01 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.12

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

15 W

15 W

PTO

21 W

21 W

PSB

15 W

15 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.23 kW

0.00 kW

Annual energy consumption Qhe

4073 kWh

5369 kWh