Certificate holders

Subtype

Tri-Thermal R290 monobloc series 4 6 kW

Certificate Holder
GD TCL Intelligent Heating & Ventilating Equipment Co., Ltd.
No. 7 Yuanlin Road,
Guangdong
China
Registration number
011-1W0856
Certification Body
DIN CERTCO Gesellschaft für Konformitätsbewertung mbH
Subtype title
Tri-Thermal R290 monobloc series 4 6 kW
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,740 kg

Certification Date
30.10.2024
Testing basis
HP KEYMARK certification scheme rules V14
Generate PDF Export model CSV
  • Number of models 4

Models

THML-4D/FBp-A
Configure model
Model name
THML-4D/FBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.20 kW

4.40 kW

El input

0.83 kW

1.40 kW

COP

5.09

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

268 %

187 %

Prated

5.30 kW

5.00 kW

SCOP

6.72

4.74

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.30 kW

4.90 kW

COP Tj = +2°C

3.48

2.43

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

6.26

4.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.90 kW

COP Tj = 12°C

8.36

6.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.40 kW

3.20 kW

COP Tj = Tbiv

6.26

4.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.48

2.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1064 kWh

1406 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

126 %

Prated

5.00 kW

4.00 kW

SCOP

4.40

3.23

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.10 kW

2.40 kW

COP Tj = -7°C

3.65

2.53

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.00 kW

1.50 kW

COP Tj = +2°C

5.49

4.01

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.50 kW

1.60 kW

COP Tj = +7°C

6.71

5.67

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.80 kW

1.80 kW

COP Tj = 12°C

7.96

6.63

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.20 kW

3.20 kW

COP Tj = Tbiv

2.68

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.40 kW

2.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.40 kW

Annual energy consumption Qhe

2880 kWh

3020 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.20

3.20

COP Tj = -15°C (if TOL<-20°C)

2.68

2.06

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

149 %

Prated

5.00 kW

4.90 kW

SCOP

5.03

3.80

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.50 kW

4.30 kW

COP Tj = -7°C

3.22

2.32

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.90 kW

2.80 kW

COP Tj = +2°C

4.76

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.40 kW

2.10 kW

COP Tj = +7°C

7.06

5.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.00 kW

1.90 kW

COP Tj = 12°C

9.29

7.15

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.50 kW

4.30 kW

COP Tj = Tbiv

3.22

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

2097 kWh

2634 kWh

THMLd-4D/3FBp-A
Configure model
Model name
THMLd-4D/3FBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.20 kW

4.40 kW

El input

0.83 kW

1.40 kW

COP

5.09

3.15

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

268 %

187 %

Prated

5.30 kW

5.00 kW

SCOP

6.72

4.74

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.30 kW

4.90 kW

COP Tj = +2°C

3.48

2.43

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.40 kW

3.20 kW

COP Tj = +7°C

6.26

4.13

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.90 kW

COP Tj = 12°C

8.36

6.26

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.40 kW

3.20 kW

COP Tj = Tbiv

6.26

4.13

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.30 kW

4.90 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.48

2.43

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.10 kW

Annual energy consumption Qhe

1064 kWh

1406 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

173 %

126 %

Prated

5.00 kW

4.00 kW

SCOP

4.40

3.23

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.10 kW

2.40 kW

COP Tj = -7°C

3.65

2.53

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.00 kW

1.50 kW

COP Tj = +2°C

5.49

4.01

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.50 kW

1.60 kW

COP Tj = +7°C

6.71

5.67

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.80 kW

1.80 kW

COP Tj = 12°C

7.96

6.63

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.20 kW

3.20 kW

COP Tj = Tbiv

2.68

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.40 kW

2.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.60 kW

1.40 kW

Annual energy consumption Qhe

2880 kWh

3020 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.20

3.20

COP Tj = -15°C (if TOL<-20°C)

2.68

2.06

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

56 dB(A)

56 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

198 %

149 %

Prated

5.00 kW

4.90 kW

SCOP

5.03

3.80

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

4.50 kW

4.30 kW

COP Tj = -7°C

3.22

2.32

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.90 kW

2.80 kW

COP Tj = +2°C

4.76

3.70

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.40 kW

2.10 kW

COP Tj = +7°C

7.06

5.21

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.00 kW

1.90 kW

COP Tj = 12°C

9.29

7.15

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.50 kW

4.30 kW

COP Tj = Tbiv

3.22

2.32

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.00 kW

4.20 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.68

2.10

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.70 kW

Annual energy consumption Qhe

2097 kWh

2634 kWh

THML-6D/FBp-A
Configure model
Model name
THML-6D/FBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

6.00 kW

El input

1.27 kW

1.94 kW

COP

4.90

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

183 %

Prated

6.00 kW

5.00 kW

SCOP

6.55

4.65

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.90 kW

5.00 kW

COP Tj = +2°C

3.34

2.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.80 kW

3.20 kW

COP Tj = +7°C

5.68

3.97

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.80 kW

COP Tj = 12°C

8.57

6.18

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.80 kW

3.20 kW

COP Tj = Tbiv

5.68

3.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.34

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

1212 kWh

1447 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

6.00 kW

5.00 kW

SCOP

4.48

3.40

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.70 kW

3.10 kW

COP Tj = -7°C

3.69

2.78

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.30 kW

1.90 kW

COP Tj = +2°C

5.63

4.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.60 kW

1.60 kW

COP Tj = +7°C

7.11

5.51

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.80 kW

1.90 kW

COP Tj = 12°C

8.03

6.99

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.90 kW

4.10 kW

COP Tj = Tbiv

2.58

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.70 kW

2.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.40 kW

Annual energy consumption Qhe

3362 kWh

3681 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.10

COP Tj = -15°C (if TOL<-20°C)

2.58

2.06

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

148 %

Prated

6.40 kW

5.90 kW

SCOP

4.85

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.70 kW

5.20 kW

COP Tj = -7°C

2.77

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.60 kW

3.30 kW

COP Tj = +2°C

4.60

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.40 kW

2.10 kW

COP Tj = +7°C

7.19

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.00 kW

1.90 kW

COP Tj = 12°C

9.40

6.95

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

5.20 kW

COP Tj = Tbiv

2.77

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.80 kW

Annual energy consumption Qhe

2739 kWh

3251 kWh

THMLd-6D/3FBp-A
Configure model
Model name
THMLd-6D/3FBp-A
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
Colder Climate + Warmer Climate
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

6.20 kW

6.00 kW

El input

1.27 kW

1.94 kW

COP

4.90

3.10

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Warmer Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

259 %

183 %

Prated

6.00 kW

5.00 kW

SCOP

6.55

4.65

Tbiv

7 °C

7 °C

TOL

2 °C

2 °C

Pdh Tj = +2°C

5.90 kW

5.00 kW

COP Tj = +2°C

3.34

2.44

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.80 kW

3.20 kW

COP Tj = +7°C

5.68

3.97

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.90 kW

1.80 kW

COP Tj = 12°C

8.57

6.18

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

3.80 kW

3.20 kW

COP Tj = Tbiv

5.68

3.97

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.90 kW

5.00 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

3.34

2.44

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.10 kW

0.00 kW

Annual energy consumption Qhe

1212 kWh

1447 kWh

Colder Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

176 %

133 %

Prated

6.00 kW

5.00 kW

SCOP

4.48

3.40

Tbiv

-15 °C

-15 °C

TOL

-22 °C

-22 °C

Pdh Tj = -7°C

3.70 kW

3.10 kW

COP Tj = -7°C

3.69

2.78

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

2.30 kW

1.90 kW

COP Tj = +2°C

5.63

4.22

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

1.60 kW

1.60 kW

COP Tj = +7°C

7.11

5.51

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

1.80 kW

1.90 kW

COP Tj = 12°C

8.03

6.99

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

4.90 kW

4.10 kW

COP Tj = Tbiv

2.58

2.06

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

3.70 kW

2.60 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.10

1.53

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

2.30 kW

2.40 kW

Annual energy consumption Qhe

3362 kWh

3681 kWh

Pdh Tj = -15°C (if TOL<-20°C)

4.90

4.10

COP Tj = -15°C (if TOL<-20°C)

2.58

2.06

Cdh Tj = -15 °C

0.900

0.900

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

59 dB(A)

59 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

191 %

148 %

Prated

6.40 kW

5.90 kW

SCOP

4.85

3.78

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.70 kW

5.20 kW

COP Tj = -7°C

2.77

2.25

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.60 kW

3.30 kW

COP Tj = +2°C

4.60

3.64

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

2.40 kW

2.10 kW

COP Tj = +7°C

7.19

5.20

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

2.00 kW

1.90 kW

COP Tj = 12°C

9.40

6.95

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.70 kW

5.20 kW

COP Tj = Tbiv

2.77

2.25

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.40 kW

5.10 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.61

2.06

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

75 °C

75 °C

Poff

10 W

10 W

PTO

10 W

10 W

PSB

10 W

10 W

PCK

0 W

0 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

1.00 kW

0.80 kW

Annual energy consumption Qhe

2739 kWh

3251 kWh