Certificate holders

Subtype

DC Inverter Heat Pump R290-07

Certificate Holder
Teon S.r.l.
Via Suor Maria Pelletier 4
20900 Monza (MB)
Italy
Registration number
041-K106-01
Certification Body
BRE
Subtype title
DC Inverter Heat Pump R290-07
Driving energy
Electricity
Heat Pump Type
Outdoor Air/Water
Refrigerant
R290
Mass of Refrigerant

0,800 kg

Certification Date
11.10.2024
Testing basis
Heat Pump Keymark Scheme Rules Rev 14
Testing laboratory
TÜV SÜD Certification and Testing Co., Ltd. Guangzhou Branch, CN
Generate PDF Export model CSV Download certificate
  • Number of models 1

Models

T07-MB
Configure model
Model name
T07-MB
Application
Heating (medium temp)
Units
Outdoor
Climate Zone
n/a
Reversibility
Yes
Cooling mode application (optional)
n/a
General Data
Power supply
1x230V 50Hz

Heating

EN 14511-2

Low temperature

Medium temperature

Heat output

4.99 kW

4.98 kW

El input

0.98 kW

1.54 kW

COP

5.08

3.24

EN 14511-4

Shutting off the heat transfer medium flow

passed

Complete power supply failure

passed

Defrost test

passed

Starting and operating test

passed

Average Climate

EN 12102-1

Low temperature

Medium temperature

Sound power level outdoor

58 dB(A)

58 dB(A)

EN 14825

Low temperature

Medium temperature

ηs

183 %

136 %

Prated

5.82 kW

5.59 kW

SCOP

4.64

3.48

Tbiv

-7 °C

-7 °C

TOL

-10 °C

-10 °C

Pdh Tj = -7°C

5.15 kW

4.95 kW

COP Tj = -7°C

3.33

2.38

Cdh Tj = -7 °C

0.900

0.900

Pdh Tj = +2°C

3.21 kW

3.03 kW

COP Tj = +2°C

4.55

3.34

Cdh Tj = +2 °C

0.900

0.900

Pdh Tj = +7°C

3.29 kW

2.93 kW

COP Tj = +7°C

6.11

4.69

Cdh Tj = +7 °C

0.900

0.900

Pdh Tj = 12°C

3.77 kW

3.66 kW

COP Tj = 12°C

7.88

6.69

Cdh Tj = +12 °C

0.900

0.900

Pdh Tj = Tbiv

5.15 kW

4.95 kW

COP Tj = Tbiv

3.33

2.38

Pdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

5.84 kW

5.58 kW

COP Tj = TOL or COP Tj = Tdesignh if TOL < Tdesignh

2.84

2.07

Cdh Tj = TOL or Pdh Tj = Tdesignh if TOL < Tdesignh

0.900

0.900

WTOL

60 °C

60 °C

Poff

6 W

6 W

PTO

20 W

20 W

PSB

6 W

6 W

PCK

42 W

42 W

Supplementary Heater: Type of energy input

Electricity

Electricity

Supplementary Heater: PSUP

0.00 kW

0.01 kW

Annual energy consumption Qhe

2590 kWh

3325 kWh