0,150 kg
Domestic Hot Water (DHW)
Warmer Climate
EN 12102-2
Sound power level indoor
51 dB(A)
Sound power level outdoor
54 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
144 %
COP
3.52
Heating up time
6:34 h:min
Standby power input
43.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
245 l
Average Climate
EN 12102-2
Sound power level indoor
51 dB(A)
Sound power level outdoor
54 dB(A)
EN 16147
Declared load profile
L
Efficiency ηDHW
130 %
COP
3.14
Heating up time
7:47 h:min
Standby power input
26.0 W
Reference hot water temperature
53.0 °C
Mixed water at 40°C
245 l
Operating test
EN 16147
Temperature operating range
passed
Safety devices checking test
passed
Condensate draining
passed